DUCTING INSTALLATION INSTRUCTIONS

Installation and service must be performed by a qualified installer or service agency.

IMPORTANT

: Have your dryer installed properly.

NOTE

: The WARNING and IMPORTANT instructions appearing in this manual are

not meant to cover all possible conditions and situations that may occur. It must
be understood that common sense, caution, and carefulness are factors that CAN-
NOT
be built into the dryer. These factors MUST BE supplied by the person(s)
installing, maintaining, or operating the dryer.

Failure to install, maintain, and/or operate this machine according to the manufacturer’s
instructions may result in conditions which can result in bodily injury and/or damage
to property.

Installation Instructions

5

SAMSUNG

Clothes Dryers Owner’s Instructions

This dryer comes ready for rear
venting.

WARNINGS

• Never use flexible duct inside the dryer.
• Do not terminate ducting in a chimney,

range hood, gas vent, floor or attic
space. The combination of lint and
grease could create a fire hazard or
cause damage.

• Provide an access for inspection and

cleaning the exhaust system at least
once a year.

EXHAUST LENGTH

The MAXIMUM ALLOWABLE length
of the ducting depends upon the type
of duct, number of turns, the type of
external venting point, and all conditions
noted below. The maximum allowable
length for both rigid and flexible metal
ducting is shown in table 1 (next page).
More than four 90°turns is not
recommended.

VENTING CHECK LIST - HOOD
or WALL CAP

• Terminate ducting in a manner to

prevent back drafts, entry of birds or
other wildlife.

• Termination should present minimal

resistance to the exhaust air flow and
should require little or no maintenance
to prevent clogging.

• Wall caps must be installed at least 300

mm (12”) above ground level or any
other obstruction with the opening
pointed down.

• If roof vents or louvered plenums are

used, they must be equivalent to a 100
mm (4”) wall cap with damper, in
regard to resistance to air flow,

prevention of back drafts and
maintenance required to prevent
clogging.

SEPARATION OF TURNS

Separate all turns by at least 1m(3ft.) of
straight duct, including distance between
last turn and dampered wall cap. If two
turns must be closer than 1 m (3 ft.)
deduct 3 m (10 ft.) from the maximum
lengths shown in the table for each occur-
rence.

TURNS OTHER THAN 90°

• One turn of 45° or less may be ignored.
• Two 45° turns should be treated as one

90°.

• Each turn over 45° should be treated as

one 90°.

SEALING OF JOINTS

• All joints should be tight to avoid leaks.

The male end of each section of duct
must point away from the dryer.

• Do not assemble the duct work with

fasteners that extend into the duct. They
will serve as a collection point for lint.

• Duct joints can be made air and

moisture-tight by wrapping the
overlapped joints with duct tape.

INSULATION

• Duct work which runs through an

unheated area or is near an air condi-
tioning duct, should be insulated to
reduce condensation and lint build up
and be sloped down toward outdoors.

NOTE

: Never install screen inside exhaust duct.

WARNING: THE DRYER MUST
VENT TO THE OUTDOORS.
TO PREVENT LARGE AMOUNTS
OF LINT AND MOISTURE FROM
ACCUMULATING AND TO
MAINTAIN DRYING EFFICIENCY,
THIS MACHINE MUST BE
VENTED OUTDOORS.