11 acoustics, 12 electromagnetic immunity, Acoustics – Seagate MOMENTUS 5400.3 ST9160821AB User Manual

Page 22: Electromagnetic immunity

Advertising
background image

16

Momentus 5400.3 PATA Blade Server Product Manual, Rev. B

2.11

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note.

For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and

power to operational levels.

2.12

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the rradio frequency (RF) environments defined in the following table:

A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.

2) No data loss.

B - 1) Unit self recovers without user intervention.

2) No data loss.

C - 1) Upset OK provided that unit will function after user intervention.

Table 3:

Drive level acoustics

Models

Idle*

Normal Seek

Performance Seek

2 Discs

ST9160821AB

ST9120822AB

ST9100828AB

2.4 bels (typ)

2.6 bels (max)

2.6

2.8

3.0 bels (typ)

3.2 bels (max)

1 Disc

ST980815AB

ST960815AB

ST9402116AB

2.2 bels (typ)

2.4 bels (max)

2.5

2.7

2.9 bels (typ)

3.1 bels (max)

Table 4:

Electromagnetic immunity

Test

Description

Performance

level

Reference

standard

Electrostatic discharge

Contact, HCP, VCP: ± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine

A

EN 61000-4-6: 97

Power Frequency H-field
immunity

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

Voltage dips, interrupts

30% Reduction for 25 cycles

>95% Reduction for 250 cycles

>95%, 0.5 cycles

C

C

B

EN 61000-4-11: 94

Advertising