Release 11/02

Unpacking and Installing the Panel PC 670/870

SIMATIC Panel PC 670/870 Start-Up Instructions

1–5

2. Panel PC 670/870 in a decentralized design

Only applies to the operating unit:

+70°

–20°

Figure 1–5

Permissible installation angles for the Panel PC 670/870 in a decentralized
design

Vertical installation as well as deviations up to +70° to
–20° in the indicated directions are permitted.

The installation position for the computer is described in Chapter 1.3.

Select the installation angle according to your own needs and continue to the next
step to define the degree of protection.

Degree of protection and type of fixation

Step 5

Applies to both centralized and decentralized designs:

The degree of protection, which you decide on, is dependent on the type of
fixation:

Protection Class IP65
This degree of protection is achieved by fixing the operating unit by means of
clamping saddles together with a seal running around the circumference.

Protection Class IP54
This degree of protection is achieved by fixing the operating unit by means of
screw mountings.

Select the degree of protection in accordance with the intended use of the
equipment and, thus, the type of fixation. After having made the selection, chose
the necessary installation cut-out.

Note

The Panel PC 670/870, 12" touchscreen is not designed for installation using
screw mountings.