I/O port characteristics

Absolute maximum voltage

-0.3 VDC to 36 VDC

Digital I/O count

Total: 4; two dedicated inputs, two
configurable input/outputs

Digital inputs

Open collector, max current 500 mA

Vih, min 2 VDC
Vil, max 0.8 VDC
Vih, max 36 VDC

Digital outputs

Open collector

Analog input count

Total: 4

Analog input

Zero-scale: 0 VDC
Full-scale: 3.3 VDC
Leakage current: 66 µA

3G Watcher software

Operating systems:
laptops

Microsoft

®

Windows

®

Vista

™, 2000, and XP

Language

English, French

62