Material safety data sheet (1/2) – Sharp FO-4650 User Manual

Page 179

Advertising
background image

177

S H A R P

Date Revised:

Date Issued :May. 28, 1999

MATERIAL SAFETY DATA SHEET (1/2)

MSDS No. B-1020

Section 1. Product Identification

Product : FO-47ND / DUNT-455BSCZZ (Toner Cartridge)

Section 2. Supplier's Name and Address

Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.

Section 3. Ingredients

Ingredients

CAS No.

Proportion

OSHA PEL

ACGIH TLV

Other Limits

Polyester resin (NJ TSRN 361615-5042-P)

>90%

Not listed

Not listed

None

Carbon black

1333-86-4

1 - 5%

3.5 mg/m

3

3.5 mg/m

3

TWA(Austl) : 3 mg/m

3

Polyolefin wax

9003-07-0

1 - 5%

Not listed

Not listed

None

Polyolefin wax

25722-45-6

(TOTAL OF BOTH)

Not listed

Not listed

None

Organic pigment (NJ TSRN 361615-5025-P)

1 - 5%

Not listed

Not listed

None

Section 4. Hazardous Identification (Emergency Overview)

Toner is a fine, black powder possessing no immediate hazard. There are no anticipated carcinogenic effects
from exposure based on animal tests performed using toner. When used as intended according to instructions,
studies do not indicate any symptoms of fibrosis will occur.

Section 5.Health Hazard Data
Route(s) of Entry
:

Inhalation?

Skin?

Ingestion?

Yes

Yes(Eye contact)

Yes

Health Hazard :
Inhalation, LC50(g/m

3

/4h) :

>0.74(Rats)* (This was the highest attainable concentration.)

Ingestion (oral), LD50(mg/kg) :

>5000 (Rats) *

Dermal, LD50 (mg/kg) :

>2000 (Rats) *

Eye irritation :

Not an irritant (rabbits) *

Skin irritation :

Not an irritant (rabbits) *

Skin sensitizer :

No data available

Mutagenicity :

Negative * (AMES test)
(* = Based on data for other products with similar ingredients)

Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen).

This classification is given to chemicals for which there is inadequate humanevidence, but sufficient ani-
mal evidence on which to base an opinion of carcinogenicity. Theclassification is based upon the devel-
opment of lung tumors in rats receiving chronic inhalationexposures to free carbon black at levels that
induce particle overload of the lung. Studiesperformed in animal models other than rats did not show
any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a
typical toner preparation containing carbon black demonstrated no association between toner exposure
and tumor development in rats.

Chronic Effect :

Prolonged inhalation of excessive dust may cause lung damage. It is attributed to “lung overloading”, a
generic response to excessive amounts of any dust retained in the lungs for a prolonged interval. Use of
this product as intended does result in inhalation of excessive dust. In a study in rats by chronic inhala-
tion exposure to a typical toner, a mild to moderate degree of lung fibrosis was observed in 92% of rats
in the high concentration (16mg/m

3

) exposure group, and a minimal to mild degree of fibrosis was

noted in 22% of the animals in the middle (4mg/m

3

) exposure group. But no pulmonary change was

reported in the lowest (1mg/m

3

) exposure group, the most relevant level to potential human exposures.

(Country)

(Name and Telephone Number)

U.S.A.

Sharp Electronics Corporation
Telephone number for information: 1-800-237-4277
Emergency telephone number : 1-800-255-3924

Canada

Sharp Electronics of Canada Ltd.
Telephone number for information: 905-890-2100
Emergency telephone number : 1-800-255-3924

all-FO4700.book Page 177 Tuesday, November 28, 2000 2:07 PM

Advertising
This manual is related to the following products: