Skylink WT-433 User Manual

Skylink Safety

Advertising
background image

1. Enter the current MPIN (Master Personal Identification Number) on the SC-001.
2. Press [B].
3. Press the number key to identify which zone to add the Door/Window Sensor to.

Note: Zone 1 and zone 2 are intended for delay mode, the other zones are for instant
alarm. Deciding on which zone you want to add the sensor depends on your
application.

4. The zone light(s) will flash for eight seconds.
5. While the zone light(s) are flashing, press [ ]. Now both the green and red lights

flash for 30 seconds.

6. While the zone lights are flashing, activate the door/window sensor by pressing

the button on the transmitter. The red LED light on the sensor will turn
on. You will hear a long beep from the control panel, the zone light will stop flash-
ing and the door/window sensor will now communicate to that zone.

Program the Door/Window Sensor to the Security Control
Panel (SC-001)

1. With only the “ON” light lit on the Audio Alarm, press

and hold the learn button located on the bottom of
the Audio Alarm.

2. While pressing down on the learn button, activate the

Door/Window Sensor by pressing the button on the trans-
mitter. The red LED light on the sensor will flash.

3. If a connection has been made, the Audio Alarm will

stop beeping and make a continuous tone until the
black learn button on the Audio Alarm is released.

4. Now test the sensor by pressing the button on the

door/window sensor again. If the Audio Alarm beeps,
they are communicating.

1. Press [L], [5] when in clock mode, the display will show

“L5 Id codE”.

2. Activate the Door/Window Sensor within 5 seconds by

pressing the button on the transmitter. The red LED light
of the sensor will be on when the button on the sensor is
pressed. The display will return to clock mode once the
Door/Window Sensor has been learned.

3. If the contact between the magnetic switch and the mag-

net is broken (door/window is opened), it will trigger the
Emergency Dialer and start dialing preset phone numbers
(refer to AD-433S, AD-1010 User’s Instruction for more
details).

Program the Door/Window Sensor to the
Audio Alarm (AA-433)

Program the Door/Window Sensor to the
Emergency Dialer (AD-433S, AD-1010)

Installation

1. Position the transmitter beside the door or window frame on the wall using either double sided

tape (temporary) or screws (recommend). If you are using screws, first pry off the back
plate with a small screwdriver and screw the back plate into position using the template.
Then click the transmitter onto the back plate mounted on the wall.

2. Position the magnetic switch connected to the transmitter on the door/window frame.
3. Position the magnet on the door beside the magnetic switch. They should be no more than

1cm (3/8 inch) apart. When the door/window is opened, contact is broken and the transmitter
sends a signal to activate the Skylink receiver(s) (Security Control Panel SC-001, Emergency
Dialer AD-433S, Audio Alarm AA-433, Silent Alarm SW-433).

*

Transmitter

Magnetic
switch

Magnet

FCC

The Remote Control is
approved by the FCC and
it complies with Part 15
of the FCC Rules. Its
operation is subject to the
following two conditions :
1. This device may not

cause harmful inter-
ference.

2. This device must accept

any interference that
may cause undesired
operation.

WARNING:
Changes or modifications
to this unit not expressly
approved by the party res-
ponsible of compliance
could void the user’s
authority to operate the
equipment.

Warranty

If, within one year from
date of purchase, this
product should become
defective (except battery),
due to faulty workman-
ship or materials, it will be
repaired or replaced,
without charge. Proof of
purchase is required.

Each Door/Window Sensor operates on a 12
volt alkaline battery that is inside the trans-
mitter. This sensor comes with the battery
already installed.
To replace the battery:
1. Push on the clip at the bottom of the trans-

mitter case with a sharp object (such as a
paper clip or pen) and pull it away from
the backplate.

2. Pry out the old battery from the end.
3. Push the new battery back into place. A dia-

gram beside the battery well indicates which
end is positive and which is negative.

4. Snap the transmitter back onto the backplate.

Battery

DOOR/WINDOW SENSOR

USER'S INSTRUCTIONS

(Model WT-433)

® are registered trademarks of their

respective corporations

®

Operation

1. Each Door/Window Sen-

sor contains 2 parts. One
is the transmitter (with the
test button), the other is
the actual sensor.

2. Test the unit by pressing

the test button on the
transmitter. If the red LED
light turns on, the unit is
ready. Once the contact is
broken, the transmitter will
transmit a signal to Sky-
link’s receiver(s).

+

-

NOTE

Skylink will not be held
liable or responsible for
any misuse or application
of this product other than
for its intended use.

I f you would like to order Skylink’s
product or have difficulty getting
them to work, please :
1. visit our website FAQ section at

www.skylinkhome.com , or

2. email us at

[email protected] , or

3. call our toll free at 1-800-304-1187

from Monday to Friday, 9 am to
5 pm EST.
fax: 1-800-286-1320

CUSTOMER SERVICE
17 Sheard Avenue, Brampton,
Ontario, Canada L6Y 1J3
Email:[email protected]
http://www.skylinkhome.com
P/N. 101A096-004
US Patent 6243000B1
©2004 SKYLINK GROUP

Advertising