Are all ff, Are all 00 – Sharp JW-20CM User Manual

Page 208

Advertising
background image

13

·

7

• Set the addresses 000600 to 000777

(8)

when the master station PC is JW model and uses a special I/O

module for slave station.

• Initial value of the address 000400 to 000407

(8)

are all FF

(H)

. Initial value of 000600 to 000777

(8)

are all

00

(H)

.

(5/6)

(same as 000600 to 000603) (No. 3)

(same as 000600 to 000603) (No. 4)

(same as 000600 to 000603) (No. 5)

(same as 000600 to 000603) (No. 6)

(same as 000600 to 000603) (No. 7)

(same as 000600 to 000603) (No. 8)

(same as 000600 to 000603) (No. 9)

(same as 000600 to 000603) (No.10)

(same as 000600 to 000603) (No.11)

(same as 000600 to 000603) (No.12)

(same as 000600 to 000603) (No.13)

(same as 000600 to 000603) (No.14)

(same as 000600 to 000603) (No.15)

(same as 000600 to 000603) (No.16)

(same as 000600 to 000603) (No.17)

(same as 000600 to 000603) (No.19)

(same as 000600 to 000603) (No.20)

(same as 000600 to 000603) (No.21)

(same as 000600 to 000603) (No.22)

(same as 000600 to 000603) (No.23)

(same as 000600 to 000603) (No.24)

(same as 000600 to 000603) (No.25)

(same as 000600 to 000603) (No.26)

(same as 000600 to 000603) (No.27)

(same as 000600 to 000603) (No.28)

(same as 000600 to 000603) (No.29)

(same as 000600 to 000603) (No.30)

(same as 000600 to 000603) (No.31)

(same as 000600 to 000603) (No.32)

000400

to

000407

Address

(8)

Set contents

Setting method (value, example)

Slave station I/O type
• Use 0 (OFF, for ZW

models) or 1 (ON,
for JW models) in
the corresponding
bits for each station
number listed on
the right.

Fix

JW-PC

ZW-PC

000600

to

000603

Data register
address of special
I/O module (No. 1)

• When the slave station 01 to 04

(8)

I/Os are ZW models and slave station

05 to 77

(8)

I/Os are JW models.

(Address)

(Bit pattern)

000400

11100000

000401

11111111

to

to

000407

11111111

Slave station number (00 to 77

(8)

)

Upper 4 bits: rack number (0, 1)
Lower 4 bits: slot number (00 to 0F

(H)

)

Number of data bytes (01 to 64

(D)

)

Register top address (file address)
D7 bit: 1 (Set), 0 (Not set)

Fix

Manual

000600

000601

000602

000603

Bit address 7 6 5 4 3 2 1 0

000400

07 06 05 04 03 02 01

000401

17 16 15 14 13 12 11 10

000402

27 26 25 24 23 22 21 20

000403

37 36 35 34 33 32 31 30

000404

47 46 45 44 43 42 41 40

000405

57 56 55 54 53 52 51 50

000406

67 66 65 64 63 62 61 60

000407

77 76 75 74 73 72 71 70

Manual

000704 to 000707

000710 to 000713

000714 to 000717

000720 to 000723

000724 to 000727

000730 to 000733

000734 to 000737

000740 to 000743

000744 to 000747

000750 to 000753

000754 to 000757

000760 to 000763

000764 to 000767

000770 to 000773

000774 to 000777

Address

(8)

Set contents

Data register address of special I/O (No.18)

(same as 000600 to 000603)

Address

(8)

000604 to 000607

000610 to 000613

000614 to 000617

000620 to 000623

000624 to 000627

000630 to 000633

000634 to 000637

000640 to 000643

000644 to 000647

000650 to 000653

000654 to 000657

000660 to 000663

000664 to 000667

000670 to 000673

000674 to 000677

000700 to 000703

Set contents

Data register address of special I/O (No. 2)

(same as 000600 to 000603)

Advertising