8.3. Elec tri cal Con nec tion

»

The elec tri cal con nec tion of the dryer and of the hop per heat ers may only be
car ried through or as signed by Ster ling ser vice staff or by qual i fied staff au -
tho rized by Sterling.

Other per sons are not per mit ted to carry through the elec tri cal con nec tion.

Ob serve the rules of the lo cal elec tric ity board.

The main switch must be freely ac ces si ble.

Ground the equip ment against elec tro static charg ing.

F

Reg u larly make sure that none of the elec tri cal or screw con nec tions are
loose.

Make sure that the main switch is at “0" po si tion be fore the elec tri cal con -
nec tion is car ried out.

The op er at ing volt age is 480/3/60

Special volt ages can be sup plied on re quest.

The con nected loads* are
STT 110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 3.2 kW;
STT 160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 3.6 kW.
*If hop per heat ers are in stalled, the value of each hop per heater must be added to these con -
nected loads (max. 9.0 kW).

The fuse pro tec tion must have 32 A.

5

0

6-

2

M

S

STT 110 / STT 160

As sem bly in struc tions 8-3