Checking installation, Electrical connections, Installation manual – Sharp Cooktop User Manual

Page 6

Advertising
background image

6

INSTALLATION MANUAL

CHECKING INSTALLATION

To check if the device is installed and engaged properly, open the

Microwave Drawer fully and gently apply medium force in the

center of the handle until movement of the appliance is detected.

Continue pressing until the Anti-Tip bracket is engaged and move-

ment stops. A small amount of movement is acceptable at the back

of the appliance top, but it should be stable and not tip once the

Anti-tip bracket is engaged. Stop pressing on the Microwave Drawer

handle and close.
To check that the unit will not slide out, open the Microwave Drawer

fully and then apply gentle outward pressure. The unit should not

slide toward you. If the unit does slide, check installation beginning

with

C

on page 5.

ELECTRICAL CONNECTIONS

ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage and fre-

quency, and connected to an individual, properly grounded branch

circuit, protected by a circuit breaker or fuse having amperage as

noted on the rating plate. (Rating Plate is located on the faceplate

behind the Microwave Drawer front.) See Figure 16.
Breaker or fuse size:

240V

40 Amps

208V

40 Amps

NOTE: Check Local Codes for required breaker size.
All electrical wiring and hookup for this appliance should be by a

qualified electrician.
Be familiar where the main appliance disconnect is located.
Check with local utilities for electrical codes which apply in your

area. Failure to wire your appliance according to governing codes

could result in hazardous conditions. If there are no local codes, your

appliance must be wired and fused to meet the requirements of the

National Electrical Codes, ANSI/NFPA No. 70-Latest Edition.
Effective January 1, 1996, the national Electrical Code requires that

new, but not existing, construction utilize a four-conductor connec-

tion for this appliance class. When installing this appliance in new

construction, a mobile home, recreational vehicle or an area where

local codes prohibit grounding through the neutral conductor, follow

the instructions in the section on NEW CONSTRUCTION AND

FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTOR.

ELECTRICAL SHOCK HAZARD

Electrical ground is required on this appliance.
• Do not connect to the electrical supply until appliance is

permanently grounded.

DISCONNECT POWER TO THE CIRCUIT BREAKER

OR FUSE BOX BEFORE MAKING THE ELECTRICAL

CONNECTION.

• This appliance must be connected to a grounded, metallic,

permanent wiring system or the grounding connector of the

power cord should be connected to the grounding terminal or

wire lead on the appliance.

• Do not use a gas supply line for grounding this appliance.
• Failure to heed these warnings could result in a fire, personal

injury or electrical shock.

I

MAKE SURE THE EDGE OF THE COUNTERTOP FITS

FLUSH AGAINST THE END OF THE FRONT CONTROL
PANEL.

See Figure 15.

Figure 15

Rating plate

Figure 16