Checking operation, Instructions for the installer – Smeg PU64 User Manual

Page 12

Advertising
background image

Instructions for the Installer

14

5. CHECKING OPERATION

After having fastened the top to the support structure, some simple procedures are required to check for
proper operation.

1)

Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety
valve.

WARNING

FIRE HAZARD

- Use a soapy solution to check for proper tightness.

- Never test for gas leaks with a match or other flames.

- Failure to follow this instruction can result in death or fire

NOTE: The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied
to the appliance.

2)

Refit the crowns, flame caps and grids on the cooktop in the
following order:

1 Fit the crowns, ensuring that they are perfectly locked into their

housing on the cooktop.

2 Fit the flame caps on the crowns, ensuring that the edges

match perfectly.

3 Fit the grids, making sure to fasten the side spokes in the

special “A” seats found on the cooktop.

These procedures must be repeated for each burner on the
cooktop.

CAUTION: refit all flame caps in the same points from which they were removed. In fact, the flame
cap positions cannot be changed. After refitting them, ensure that they are fitted perfectly and
that there is no clearance between the top and the flame caps.

3)

The cooktop's electrical circuit can be checked for proper operation
only after top assembly has been completed as described in step
2) and you have checked to ensure that all parts have been fitted
properly:

1 a spark must light on all burners when the knobs on the top are

pressed

2 when each knob on the cooktop is pressed and turned to the

min flame symbol ( ), the entire crown should light.

3 lf burners do not light properly, turn the control knob to the

"OFF" position . Check that burner caps and crowns are in
the proper position. Check that the power supply cord is
plugged in and that circuit breaker or house fuse has not blown.
Check that the shut-off valve is in the "ON" position. Check
operation again. lf a burner does not light at this point, contact
your dealer for assistance.