CIRCUIT DESCRIPTION

The APC voltage controls the gate voltage of Q11 and Q12,

and keeps transmission output stable.

The MPU detects power supply voltage and controls Q58

by transmission power supply voltage and transmission power.
For example, if the power supply voltage during transmission,
is equal to or higher than approx. 10.5 V and if power is at Mid
or Low level, the APC voltage level applied to Q12 is reduced
by Q58.

Temperature Protection Circuit

To prevent thermal destruction of the power amplifier (Q12),

this circuit reduces APC voltage when Q12 temperature rises.

The MPU (IC8) detects temperature with a thermistor (TH1)

and controls reference voltage to the APC circuit.

PLL System

PLL Circuit

A reference frequency of 5 kHz or 6.25 kHz is produced by

dividing the 12.8 MHz reference frequency of the TCXO (X1)
with PLL IC (IC1). Comparison frequency is produced by

TCXO

PLL IC

IC1

LOOP

FILTER

TO

TCXO

5C
5/0V

5MS
5/0V

PLL

5C
5/0V

VC

X1

12.8MHz

CLOCK

DATA

LE

Fo/LD

IF

Rectifier

LPF

Q6

RF

Amp

D1,D2

VCO

5C
5/0V

LV
1~5V

SHIFT

H/L

Ripple

Filter

Q4

OSC

Q1

Buff

Amp

Q2

RF

Amp

Q5

SW

D8,D9

MOD

SHIFT

SW

Q3

MOD

12.8MHz

TX

RX

5T 5/0V

5R 5/0V

VR1

Fig. 8 PLL and VCO circuit

amplifying VCO output with an RF amplifier (Q6) and dividing
it with the PLL IC.

The PLL synthesizer with 5 kHz and 6.25 kHz step is

configured by comparing phases of the reference frequency
and comparison frequency.

The phase difference between reference frequency and

comparison frequency passes through a charge pump in the
PLL IC, then ripples are removed with a loop filter with low-
range passing characteristics to produce VCO control voltage
(lock voltage).

VCO Circuit

The VCO produces a desired frequency directly with a

Colpits oscillation circuit containing an oscillation transistor (Q1)
used for both transmission and reception.

The VCO control voltage is applied to varicap (D1, D2) to

produce a desired frequency.

The SHIFT terminal (pin 113) of the MPU (IC8) goes "H"

during reception, and the shift control switch (Q3) is turned
ON to change oscillation frequency.

Fo/LD

PLL LD

IC8

MPU

IC1

PLL IC

R32

D16

C40

R35

14

102

5C

Fig. 9 Unlock detection circuit

Unlock Detection Circuit

When the PLL is unlocked, the waveform of the pulse

output from the Fo/LD terminal (pin 14) of the PLL IC (IC1) is
rectified with R32, D16, R35 and C40, and the Fo/LD terminal
is made “L” level. The voltage at the Fo/LD terminal is
detected by the MPU to control transmission/reception
switching timing.