Error response defines the action taken when a document shorter
than the minimum length or longer than the maximum length is fed
into the Scanner 5500/7500.

The default for all modes is

Display and Beep.

The options are:

— Display Error Message—results in an error message appearing

on the Operator Control Panel (E106–Doc Length Monitor
Warning).

Display and Beep—results in an error message appearing on the
Operator Control Panel (E106–Doc Length Monitor Warning),
accompanied by an error tone.

Stop, Display, & Beep—which results in the transport shutting
down, and an error message appearing on the Operator Control
Panel (E214–Re-Scan-Length Monitr Er), accompanied by an
error tone.

Select

Error Response from the Length Monitor menu.

Single
6006
3111
Supprs
FthenR
None
Off
Off
NA NA

Index Format
IA Field Width
Level Rules
IA Display Format
Adjoining IA
Batching
Length Monitor
Skew Monitor
Footswitch

Patch Reader
COIN2 Port Select
OCR
Bar Code Reader
Printr Controller
Front Printer
Rear Printer
Mode Name
Overrides

Off
n/a
n/a
Off
Supprs
Off
Off
MODE0
No Sav

Save & End Session

Save & Prev Menu

Don't Save & End Session

Don't Save & Prev Menu

Mode Number: 01 Mode Name: MODE01 Item #: 7.4

Mode Configuration

Length Monitor
On/Off
Minimum Length
Maximum Length
Error Response

Previous Menu

Error Response
Display Error Message
Display and Beep
Stop, Display, & Beep

Previous Menu

Select the desired error response.

Press

Enter.

Error response