Kenmore 625.348460 User Manual

Page 20

Advertising
background image

SERVICE TECH. INFORMATION

SECTION 5

20

5A.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate computer has a selfĆdiagnostic

function for the electrical system (except input

power and water meter). The

computer monitors the electronic

components and circuits for corĆ

rect operation. If a malfunction occurs, an error

code appears in the face plate display.

The chart below shows the error codes that could

appear, and the possible defects for each code.
While an error code appears in the display, all face

plate buttons are inoperable except the SELECT

button. The SELECT button remains operational

so the service person can make the MANUAL

INITIATE ELECTRONIC DIAGNOSTICS to further

isolate the defect, and check the water meter.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Err 01

motor inoperative / wiring harness or connection to switch / position switch / face plate

Err 02

face plate

Err 03

motor inoperative / face plate

Err 04

face plate / position switch

Err 05

face plate

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect
3. Plug-in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

MANUAL INITIATED ELECTRONICS DIAG-
NOSTICS

1

.

To enter diagnostics, press and hold the

SELECT button until 000 - - shows in the

display.

A

.

The first 3 digits indicate water meter operaĆ

tion as follows:
000 (steady) = Soft water not in use, and no

flow through the meter.

Ċ OPEN A NEARBY SOFT WATER FAUCET Ċ

000 to 199 (continual) = Repeats display for

each gallon of water passing through the meĆ

ter.
If you don't get a reading in the display, with

the faucet open, pull the sensor from the valve

outlet port. Pass a small magnet back and forth

in front of the sensor. You should get a reading

in the display. If you get a reading, unhook the

in and out plumbing and check the turbine for

binding.

B

.

The letter (P) and dash (or dashes) indicate

POSITION switch operation. If the letter apĆ

pears, the switch is closed. If the dash shows,

the switch is open.
Use the ON/OFFĆHOLD (Recharge Now) butĆ

ton to manually advance the valve into each

cycle and check correct switch operation.

Advertising