5C. WATER FLOW THROUGH THE SOFTENER VALVE

FAST RINSE CYCLE

During FAST RINSE, the rotor & disc is positioned so water flow enters the

resin tank through the top distributor, and exits through the bottom

distributor, to the drain.

The solid state timer again energizes the motor to return the valve to service.

As the valve rotates, the position switch lever drops to open the circuit. The

valve remains positioned in service until the timer initiates the next

regeneration.