33

Replacement of fuses

Servicing

Cleaning the projector

WARNING:

For safety, always turn the machine

off, unplug the mains lead and allow

the projector to cool down before

cleaning.

Housing:

Wipe the housing with a soft, cotton cloth

and use a cleaner designed for plastic ma-

terials. Do not use solvents or spirit based

cleaners.

Optics:

Do not touch optical surfaces!

Clean the lens with a soft lintfree cloth or

with special lens tissues.

Never wipe over a dry surface!

Use a special lens cleaner (available from

photographic dealers) or add moisture by

breathing over the parts to be cleaned.

WARNING:

Always switch off the projector and unplug the mains lead before replacing a

fuse!

Avoid the risk of fire, replace only with a fuse of same type and rating!

The electric circuits in your projector are protected by three fuses which you can replace

yourself. The casing need not, therefore, be opened.

Replacement of secondary circuit fuses

Please note:

These fuses are different! See technical data, page 37.

Two secondary fuses protect the projector against damage caused from too higher current

drawn by external equipment connected to the projector’s remote socket or to the module

expansion slot.

1.

Turn the fuse carrier (29) anti-clockwise with a screwdriver or a coin.

2.

Replace the defective fuse. (Technical data, page 37).

3.

Re-screw the carrier clockwise into position.

Replacement of primary circuit fuses

1.

Pull out the fuse link compartment

(31). Do not change the position of the fuse

holder when reinserting into the projector

(see also page 26).

.

Replace the defective fuse (33) (tech-

nical data, page 37).

.

Push the fuse link compartment back

into the projector.

Maintenance and

guarantee

1.

1.

2.

Reliability and sturdiness are important

features of your EKTAPRO Slide Projector.

The projector should be periodically serv-

iced as needed to prolong its life. Dirt and

dust can have adverse effects on the lubri-

cants used in the projector and thus can

cause malfunctions. With the help of the

built in micro-processor your Kodak serv-

ice center can make a fast and reliable diag-

nosis of the projector.

Defective or worn parts can be detected

and replaced or repaired. We recommend

routine maintenance approximately every

1500 hours of operation or three years

whichever comes first.

Where the projector is used in very dusty

locations (e.g. exhibitions) more frequent

servicing will be needed.