Troubleshooting – Kenwood TH78E User Manual

Page 58

Advertising
background image

TROUBLESHOOTING

The following problems are generally caused by

improper transceiver operation or connection, not by

defective components.

If you experience any of these problem causes and

corrective actions before requesting service.

Symptom

Probable Cause

Corrective Action

Indicators do not light and no

1. Low voltage.

1. Recharge/ replace the battery.

receiver noise is heard when the

2. With optional DC cable:

2.

POWER switch is turned on.

1) Bad power cable or

1) Check cables and connections.

connections.

2) Blown power supply fuse.

2) Check for the cause of the

blown fuse and replace the fuse.

No sound from the speaker.

1. Squelch is closed.

1. Turn the SQL control

No signal can be received.

2. With the TSU-7: CTCSS is

counterclockwise.

operating.

2. Press the F key, then press the 3

key to turn off the CTCSS.

3. DTSS is operating.

3. Press the F key, then press the 2

key to turn off the DTSS.

4. Paging is operating.

4. Press the F key, then press the 1

key to turn off the Paging.

No control works.

1. LOCK is ON.

2. T.ALT is ON.

1. Press the F key, then press the M

key.

2. Press the F key, then press the 5

key.

Memory channel cannot be

Nothing is stored in the memory

See Using the Memory (page 19)

recalled.

channel.

Memory cannot be backed up.

1. Battery voltage is low.

1. Recharge the battery.

2. Battery case removed.

2. Install the Battery case.

60