Programs and combinations – KORG Krome music workstasion 61key User Manual

Page 131

Advertising
background image

Troubleshooting Programs and Combinations

127

Alternatively, are all Solo button settings turned off? 

→ p.46
If a specific track doesn’t sound in Sequencer mode, is 
its Play/Rec/Mute button set to Play? Alternatively, are 
all Solo button settings turned off? 

→ p.55

Make sure that the Status is INT or BTH. 

→ p.50, p.57

Are the Key Zone and Velocity Zone set so that sound 
will be produced when you play? 

→ PG p.14, p.84, 

p.129

Is the Oscillator, Drum Track, Timbre, or Track level 
lowered in the control surface mixer? 

→ p.27, p.46, p.55

Could the level of the Master Volume following the 
total effect have been lowered? 

→ PG p.62, p.99p.152

Could the total polyphony be exceeding the maximum 
polyphony of 120 voices? 

→ p.32

Notes do not stop

In Prog P1: Basic/Controllers– Note‐On/Scale, select 
the Program Basic page, make sure that the Hold check 
box is unchecked. 

→ PG p.14

Did you use Tone Adjust to turn Hold on? 

→ PG p.10

In Global P2: Controller, make sure that Damper 
Polarity
 or Foot Switch Polarity is set correctly. 

→ PG p.202
If the DRUM TRACK or ARP buttons are turned on, 
try turning them off.

Notes are sounded in duplicate

Is Local Control turned Off?

• Clear the Local Control On checkbox (Global P1: 

MIDI). 

→ PG p.198

Noise or oscillation is heard

When using the MIDI/Tempo Sync function to control 
the delay time of an effect, noise may occur in the delay 
sound. This noise is due to discontinuities in the delay 
sound, and is not a malfunction.
Some effects, such as 019: Stereo Analog Record, 
generate noise intentionally. It is also possible to create 
oscillation using a filter with resonance. These are not 
malfunctions.
Note that if you use the following effects with the 
routing described below, a feedback loop will be 
created, possibly producing a loud noise. Please use 
caution.
If the signal from an oscillator or timbre/track output, 
or the signal after an insert effect, is sent to the FX 
Control bus and that signal is output directly, with this 
output sent to the FX Control bus, a loud noise may be 
output. (It is also possible that a DC component will be 
output at the maximum level, producing silence.)

• When using the 003: Stereo Limiter or 006: Stereo 

Gate, and the Envelope Source of these effects is set 
as either FX Control 1 or FX Control 2, and Trigger 
Monitor
 is On.

• When using 174: Vocoder, with the Modulator 

Source set to FX Control 1 or FX Control 2, and the 
Modulator High Mix set to other than 0.

Can’t play chords

Could the program’s Voice Assign Mode be set to 
Mono? 

→ p.33

Pitch is incorrect

• In the Global P0: Basic Setup page, are the Master 

Tune and Transpose settings correct? 

→ p.109

• In the Prog P2: OSC/Pitch page, is the Pitch Slope 

set to +1.0? 

→ PG p.20

• In the combination or song, are the Transpose and 

Detune settings of each timbre/track set 
appropriately? 

→ PG p.82, p.127

• In the timbre/track settings of each program, 

combination, or song, could you have selected a 
non‐standard scale type other than Equal 
Temperament? 

→ PG p.15, p.83, p.128

Programs and Combinations

Settings for oscillator 2 are not displayed

Make sure that the Oscillator Mode (Prog P1: Basic/
Controllers) parameter is set to Double or Double 
Drums. 

→ p.32

Program does not sound

Could the oscillator or amp level be lowered? 

→ PG p.5, p.6, p.35
Could the program be muted?

• Use the Play/Mute button in the Prog P0: Play– 

Mixer & Drum Track page to mute/unmute a 
program, or in the Combi P0: Play– Program T01–
08 and T09–16 pages to mute/unmute a 
combination.

A combination does not play correctly after
you load data

In the dialog box when you saved the data, did you 
check the items that you wanted to save? 

→ PG p.231

Are the bank/numbers of the programs used by the 
combination the same as when the combination was 
created?

• If you have switched program banks, you can use 

the Global mode Change all bank references menu 
command to change the program bank for each 
timbre of a combination. 

→ PG p.216

Can’t write a Program

Is the Memory Protect Program or Combination 
checkbox (Global P0) cleared? 

→ p.110, and PG p.197

Advertising
This manual is related to the following products: