CARE OF YOUR SOFTENER

SECTION 3

16

3C.

KEEP THE SOFTENER FROM FREEZING

If the softener is installedwhere it couldfreeze

(summer cabin, lake home, etc.), you must drain

all water from it to stop possible freeze damage.

To drain the softener Ċ
1. Close the shutĆoff valve on the house main

water pipe, near the water meter or pressure

tank.

2. Open a faucet in the soft water pipes to vent

pressure in the softener.

3. Looking at FIG. 16 on page 21, move the stem

in a single bypass valve to bypass. Close the

inlet andoutlet valve in a 3Ćvalve bypass

system, andopen the bypass valve. If you want

water in the house pipes again, reopen the

shutĆoff valve on the main water pipe.

4. Unplug the transformer at the wall outlet.

Remove the salt hole cover andthe main

cover. Take off both drain hoses.

5. Carefully remove the large holding clips at the

softener inlet andoutlet (see Key No. 61, on

page 34). Separate the softener from the

adaptors or bypass valve.

6. Remove the brinewell cover anddisconnect

the brine valve tubing at the nozzle andventuri

assembly (see page 34). Lift the brine valve out

of the brinewell. Tip the brine valve upside

down to drain out water.

FIG. 14

DRAIN WATER FROM THE
SOFTENER

wood block

floor drain

7. Looking at FIG. 14, lay a piece of 2 inch thick

boardnear the floor drain. Move the softener

close to the drain. SLOWLY and CAREFULLY

tip it over until the rim rests on the woodblock

with the inlet andoutlet over the drain. Do not

allow the softener's weight to rest on the

inlet and outlet fittings or they will break.

8. Tip the bottom of the softener up a few inches

andholduntil all water has drained. Leave the

softener laying like this until you are ready to

use it. Plug the inlet andoutlet with rags to

keep dirt, bugs, etc. out.