Servicer’s tech. information, 5c. troubleshooting – Kenmore 625.3483500 User Manual

Page 24

Advertising
background image

SERVICER’S TECH. INFORMATION

SECTION 5

24

5C.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate has a selfĆdiagnostic function for the

electrical system (except input power). The face plate

monitors the electronic components and circuits for

correct operation. If a malfunction

occurs, an error code appears in the

face plate display

.

The chart below shows the error codes that could

appear, and the possible defects for each code.

While an error code appears in the display, all face

plate buttons are inoperable except the SET button.

The SET button remains operational so the service

person can make the MANUAL ADVANCE DIAGNOSĆ

TICS to further isolate the defect.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

E—1

motor inoperative / wiring harness or connection to switch / switch / face plate

E—2, E—3

face plate

E—4

face plate / position switch

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect 3.

PlugĆin transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

FACE PLATE REPLACEMENT: Be sure the valve is in service position (observe valve cycle indicator. . . see

below) when replacingthe face plate.
If, after installing and programming the replacement face place, the valve is not in service position, do the followĆ

ing to assure correct cycle orientation, or timing, between the face plate and valve.
Use the MANUAL ADVANCE procedures, below. With the RECHARGE NOW button, advance through the recharge

cycles until the valve stops in service position, and RECHARGE no longer flashes in the timer.

NOTE: The valve motor may automatically drive through several valve positions while searching for service.

MANUAL ADVANCE DIAGNOSTIC

Use the following procedures to advance softener

valve through regeneration cycles to check operation.

Remove top cover to observe valve rotation.

DISPLAY MUST SHOWTIME AND DAY

1

.

Press and hold  for 3 seconds until

18:88 displays.

2

.

Press  to display position (P) switch open or

closed indicator.

If the valve is in service, fill, brining,

backwash or fast rinse (see markings on

cam under motor), the display will

show

(- -), meaning the position

switch is open.

While the valve is

rotating from 1 cycle to

another, the display

will show (- P), meanĆ

ing the position switch

is closed.
3

.

To advance valve,

press  each time

you want to move

into next cycle.

(Pressing  while

valve is rotating has

no affect.)

ĊPress and hold  for 3 seconds to

move softener into fill cycle. Remove

brinewell cover and, using a flashlight,

observe fill water entering tank.

continued

CAM

MOTOR

position
markers

Advertising