Features

• Provides a complete AUI to thin Ethernet (10Base2)

interface including:

— Transmit function
— Receive function
— Collision presence function
— Jabber function
— SQE (Signal_Quality_Error) test

• Supports data transfer rate of 10Mbps
• Capability for driving the coaxial trunk cable

segment up to 185M (600 ft.) without a repeater

• CSMA/CD access mechanism
• Selectable SQE test
• Power LED indication
• Dimension:

42mm x 65mm x 20mm

• Input voltage:

10.2 to 15.75 VDC

• Input current:

250mA @12 VDC (typical)

Connectors & Cables

BNC connection:BNC female connector

RG-58A/U thin coaxial cable

AUI connection: D-sub 15 pin male connector

AUI drop cable (50 meters max.)

Pin Assignments of the AUI (DB15) Connector

Pin

Name

Pairs

Use

3

DO +

Transmit

Data Out (+)

10

DO -

Pair

Data Out (-)

11

DO S

Data Out Shield

5

DI +

Receive

Data In +

12

DI -

Pair

Data In -

4

DI S

Data In Shield

7

CO +

Optional

Control Out +

15

CO -

Pair

Control Out -

8

CO S

Control Shield

2

CI +

Collision

Control In +

9

CI -

Pair

Control In -

1

CI S

Control Shield

6

VC

Power

Voltage Common

13

VP

Pair

Voltage Plus

14

VS

Voltage Shield

Installation

1. Connect a BNC T-connector to the BNC female

connector on the transceiver, then connect thin
coaxial cable to the T-connector. If the T-connector is
located at the end of the cable segment, plug a 50
ohm BNC terminator onto another female end of the
T-connector.

2. A standard AUI cable (50M max.) is required to

connect the transceiver to the AUI port of Ethernet
device. Or, you may directly mount the transceiver to
the AUI port.

Setting Switches

Switch Setting

Function

SW1 ON

Enable 50ohm cable terminator

SW1 OFF

Disable 50ohm cable terminator

SW2 ON

Enable SQE test

SW2 OFF

Disable SQE test

The 50ohm cable terminator is built in the transceiver. If
the transceiver is located at the end of a thin coaxial
cable, the built-in terminator can be enabled to eliminate
the need for plugging an external BNC terminator.

The transceiver is shipped from the factory with the SQE
test enabled. Depending on the Ethernet device to which
the AUI connector attaches, you can set the SW2 switch
to "OFF" position to disable the SQE test function or set
the switch to "ON" position to enable the SQE test
function.

If the transceiver is connected to an Ethernet repeater, a
10Base-T hub, or a wiring concentrator, the SQE test
function should be disabled.

General Description

The KT-10B Ethernet transceiver complies with IEEE
802.3 transceiver specifications and 10Mbps Ethernet
CSMA/CD operation to provide a connection interface to
thin Ethernet coaxial cable.

The transceiver is attached to the AUI connector of an
Ethernet device via standard AUI cable.