Customer responsibilities product specifications – Kenmore THE ECONOMIZER 153.33206 User Manual

Page 5

Advertising
background image

5

TANK

RECOVERY

MINIMUM

CAPACITY

INPUT

RATE GALS.

VENT PIPE

DIAMETER

DIMENSIONS IN

MODEL

IN GALS.

TYPE OF

RATE

PER HOUR

INCHES

INCHES

INCHES (mm) HEIGHT

NUMBER

(LTRS)

GAS

(Btu/hr)

@ 90°F RISE

(mm)

(mm)

TO JACKET TOP

153.332040

40 (151)

NATURAL

40,000

44

2 (51)

18 1/2 (470)

55 (1,397)

153.332050

50 (189)

NATURAL

40,000

44

2 (51)

20 (508)

56 3/4 (1,441)

153.332060

40 (151)

PROPANE

40,000

44

2 (51)

18 1/2 (470)

55 (1,397)

153.332070

50 (189)

PROPANE

40,000

44

2 (51)

20 (508)

56 3/4 (1,441)

Thank You for purchasing a Kenmore water heater. Properly installed
and maintained, it should give you years of trouble free service. If you
should decide that you want the new water heater professionally installed
by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality
installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

• CSA - Canadian Standards Association
• ANSI - American National Standards Institute
• NFPA - National Fire Protection Association
• ASME - American Society of Mechanical Engineers
• GAMA - Gas Appliance Manufacturer’s Association
• UL - Underwriters Laboratories Inc.

This gas-fi red water heater is listed by Underwriters Laboratories Inc.
under American National Standard/CSA Standard for Gas Water Heaters
ANSI Z21.10.1 • CSA 4.1 (current edition).

PREPARING FOR THE INSTALLATION

1. Read the “Safety Precautions” section, page 3 of this manual fi rst and

then the entire manual carefully. If you don’t follow the safety rules,
the water heater will not operate properly. It could cause DEATH,
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation,
and maintenance of the gas-fi red water heater. It also contains
warnings throughout the manual that you must read and be aware
of. All warnings and all instructions are essential to the proper
operation of the water heater and your safety. Since we cannot put
everything on the fi rst few pages, READ THE ENTIRE MANUAL
BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER
HEATER.

2. The installation must conform with these instructions and the local code

authority having jurisdiction. In the absence of local codes, installations
shall comply with the National Fuel Gas Code ANSI Z223.1/NFPA
54 and the National Electrical Code, NFPA 70. These publications
are available from The National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02269.

3. The water heater when installed must be grounded in accordance

with the local codes, or in the absence of local codes, the National
Electrical Code NFPA 70.

4. If after reading this manual you have any questions or do not

understand any portion of the instructions, call the local gas utility or
the Sears Service Center.

5. Carefully plan the place where you are going to put the water heater.

Correct combustion, vent action, and vent pipe installation are
very important in preventing death from possible carbon monoxide
poisoning and fi res.

Examine the location to ensure the water heater complies with the
“Facts to Consider About the Location” section in this manual.

6. For California installation this water heater must be braced, anchored,

or strapped to avoid falling or moving during an earthquake. See
instructions for correct installation procedures. Instructions may be
obtained from California Offi ce of the State Architect, 400 P Street,
Sacramento, CA 95814.

7. Massachusetts Code requires this water heater to be installed in

accordance with Massachusetts 248-CMR 2.00: State Plumbing Code
and 248-CMR 5.00. For more information see next page.

CUSTOMER RESPONSIBILITIES

PRODUCT SPECIFICATIONS

Advertising
This manual is related to the following products: