9.2 Remote Control Connection Options

This section gives the available options for connecting HELIX DN9340E, DN9340, DN9344E and DN9344

units - and also HELIX DN9848E and DN9848 units - to enable remote control via a laptop or PC.

All units in a system must be running the same protocol version. The protocol version is determined by

the first digit in the software version, for example, if a DN9340E unit was running host software version

4.00, the protocol version is 4.

Note

Although there are many combinations available for remote operation, it is always worthwhile

remembering that Ethernet provides faster operation than serial.

9.2.1

Single-unit serial connections

Note

The following converters are the only converters supported by Klark Teknik. Even

though other converters may seem to work, we cannot guarantee their correct
functionality and compatibility when used with our products.

To connect a single unit via serial RS-232

The KT RS-232 host cable (supplied with every unit) is connected to the front panel of the unit and then

to the RS-232 port on the laptop/PC.

To connect a single unit – USB to front panel

The KT RS-232 host cable (supplied with every unit) is connected to the front panel of the unit and then

to a KK Systems USB232 USB-to-serial converter. The converter is then connected to a USB port on the

laptop/PC via a USB cable.

To connect a single non-Ethernet unit – USB to rear panel

A serial RS-485 cable is connected to the rear panel of a DN9848, DN9340 or DN9344 unit and then to a
B+B Systems USOTL4 USB-to-RS-485 converter, using a serial RS-485 cable. The converter is then

connected to a USB port on the laptop/PC via a USB cable.