Note: Diagrams aND illustratioNs are Not to scale.

4

adhere to all local codes or in their absence the latest edition of the

National Fuel gas code aNsi Z.1 or NFPa 54-latest edition which can

be obtained from the american National standards institute, inc. (140

Broadway, New York, NY, 10018) or National Fire Protection association,

inc. (Batterymarch Park, Quincy, ma, 069).

state or local codes may only allow operation of this appliance in a vented

configuration. check your state or local codes.

Seller of unvented propane or natural gas-fired supplemental room

heaters shall provide to each purchaser a copy of 527 CMR 30 upon

sale of the unit (Stand. This is a standard Unvented Propane or Natural

Gas-Fired Space Heaters

shadowdance™ gas log appliances are certified by omNi-test labora-

tories to aNsi Z1.11. unvented room heaters standard. these gas log

appliances may be used as a space heat source for a room in conjunction

with an approved unvented firebox.

additionally, these units are design certified by omNi-test laboratories

to aNsi 1.60b / csa .6b Decorative appliance. For installation in

solid-fuel burning fireplaces.

as such, these units may be used as a vented gas log set in any wood-

burning fireplace that has been properly constructed to code, and in the

case of factory built fireplaces, installed in compliance with manufacturers

listing and installation instruction.

use of the log sets covered by this manual in a properly vented wood-

burning fireplace which has had the damper blocked open as detailed

below, preclude consideration of the combustion and ventilation air and

clearance to combustible restrictions discussed herein.

When local codes require the damper to be fixed open, a damper stop must

be installed to prevent full closure of the fireplace damper and provide a

minimum 9 square inch flue opening at all times.

This appliance is for installation in a solid fuel burning fireplace

(masonry fireplace or manufactured fireplace) with a working flue and

constructed of noncombustible material.

The minimum permanent free opening of the fireplace chimney or

chimney damper must be at least 29 sq. inches based upon a minimum

chimney height of at least 15 feet. Chimney damper must be fixed in

a manner to maintain permanent free opening at all times.

NEW YORK CITY, NEW YORK (MEA)

installation of these gas log heaters are approved in the state of New York

and are prohibited in New York city.

CODES

SEE TABLE 3 ON PAGE 16 FOR BTU INPUT AND GAS PRESSURE

REQUIREMENTS

Do not install these Dual-Listed Gas Log Appliances in a bedroom or

a bathroom as all units exceed maximum allowable BTU/hr input of

10,000.

Tools and Supplies Normally Required

external regulator (Propane models only)

manual shut-off valve

sediment trap

Piping complying with local codes

Pipe compound

Pipe wrench

tee joint

screwdriver

Burn-in Period

During the first few times of operation of this appliance there will be some

odor due to the curing of the paint and burning off of lubricants used

in the manufacturing process. We recommend that you open windows

and ventilate the house during the initial burns. the paint emits non-toxic

odors during this process.

Depending on your use, the burn-in period may take a few hours or a few

days. also if you have a sensitive sense of smell you may notice slight

odors during operating after the burn-in period is over.

KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD.

THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE

QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. MAKE

SURE SMOKE DETECTORS ARE NOT TOO CLOSE TO THE FIREBOX

(CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES).