(13) Setting BER measurement interval ...."BI"

Function

Setting and querying BER measurement interval.

Syntax BI_p (Setting,

reply)

BI_? (Query)

BER measurement interval p: 0.1 to 3600.0 sec.

Effective down to one digit after the decimal point.

The value set in second is converted into the number of packets ; it cannot be set in
number of packets.

Notes on program code for (8) to (13)

When TS input is set other then the PN, both setting and querying operations are
disabled.


(14) Setting RF channel............................."CH"

Function

Setting and querying RF channel (VHF, UHF, CATV).

Syntax CH_n

(Setting,

reply)

CH_? (Query)

n RF channel

VHF, UHF, CATV channel

n, STD

STD setting of USA CATV channel

n, IRC

IRC setting of USA CATV channel

n, HRC

HRC setting of USA CATV channel

This program code is ignored when querying channel set in frequency.


(15) Setting RF frequency.........................."RF"

Function

Setting and querying RF frequency.

Syntax RF_i (Setting,

reply)

RF_? (Query)

i RF frequency:

50.000 to 900.000 (MHz), effective down to three digits after
decimal point

This program code is ignored when querying channel set in channel.


(16) Incrementing frequency or channel ...."FU"

Function

Incrementing frequency in current steps when RF is set in frequency.
Incrementing channel by one when RF is set in channel.

Syntax FU (Setting)


(17) Decrementing frequency or channel .."FD"

Function

Decrementing frequency in current steps when RF is set in frequency.
Decrementing channel by one when RF is set in channel.

Syntax FD (Setting)