Chapter 11. Monitoring

z

User display select

Group

LED

Display

Parameter Name

Set

value

Min/Max

range

Factory

default

Unit

Drive
group

vOL

[User display select]

-

Function
group 2

H73

[Monitoring item select]

-

0/2

0

ƒ The selected item in H73- [Monitoring item select] can be monitored in vOL- [User display select].



H73: Select one of the desired item numbers.

0

Output voltage [V]

1

Output power [kW]

H73 [Monitoring

item select]

2 Torque

Enter motor efficiency indicated on motor nameplate to H36 to display correct torque

z Power on display

Group

LED

display

Parameter Name

Setting

Factory

default

H72

[Power on display]

0

Frequency command (0.0)

1

Accel time (ACC)

2

Decel time (DEC)

3

Drive mode (drv)

4

Frequency mode (Frq)

5

Multi-step frequency 1

6

Multi-step frequency 2

7

Multi-step frequency 3

8

Output current (CUr)

9

Motor rpm (rPM)

10

Inverter DC link voltage
(dCL)

11

User display select (vOL)

12

Fault display 1

Function
group 2

`

13

Fault display 2

0

ƒ Select the parameter to be displayed on the keypad when the input power is first applied.

101