14. Specifications

command, H/W fault

Alarm
Conditions

Stall prevention, Overload

Momentary
power loss

Less than 15 msec: Continuous operation
More than 15 msec: Auto Restart enable

z Environment

Cooling
method

Forced air cooling

Degree of
protection

Open, Pollution degree 2

Ambient
temperature

-10 ~ 50°C (14 ~ 122°C)

Storage
temperature

- 20 ~ 65°C (-4 ~ 149°C)

Relative
humidity

Less than 90% (no condensation)

Altitude,
Vibration

1,000m (3000 ft) above sea level, Max. 5.9m/sec

2

(0.6G)

Application
site

Protected from corrosive gas, combustible gas, oil mist or dust

14.2 Temperature Derating Information

z Load current VS Carrier frequency















For 2.2kW inverter

For 0.4kW, 0.8kW, 1.5kW inverter

Load

Current

Load

Current

100%

100%

80%

1kHz 15kHz

1kHz

8kHz

15kHz

Carrier freq.

Carrier freq.

Note:

1. The above graph is applied when inverter is in use within the permissible ambient

temp. If the unit is installed in a panel, install it where heat dissipation is properly done
to keep the panel ambient temp within permissible range.

2.

This de-rating curve is based on inverter current rating when rated motor is connected.

123