LG C Series User Manual

Page 40

Advertising
background image

Chapter 6. Basic operation

Frequency Setting via potentiometer & operating via terminals

1

-. Apply AC input power to the inverter.

2

-. When 0.0 appears Press the Up (

S) key four times.

3

-. Frq is displayed. Frequency setting mode is selectable.
-. Press the Prog/Ent (

z) key once.

4

-. Present setting method is set to 0 (frequency setting via keypad).
-. Press the Up (

S) key twice.

5

-. After 2 (Frequency setting via potentiometer) is set, press the Prog/Ent (

z) key once.

6

-. Frq is redisplayed after 2 stops blinking.
-. Turn the potentiometer to set to 10.0 Hz in either Max or Min direction.

7

-. Turn on the switch between P1 (FX) and CM (See Wiring below).
-. FWD lamp begins to blink and the accelerating frequency is displayed on the LED.
-. When run frequency 10Hz is reached, the value is displayed as shown left.
-. Turn off the switch between P1 (FX) and CM terminals.

8

-. FWD lamp begins to blink and the decelerating frequency is displayed on the LED.
-. When the run frequency is reached to 0 Hz, FWD lamp is turned off and 10.0 is
displayed as shown left.

220VAC

L1(R)

L2(S)

P

P1

N

G

P1(FX)

CM

U

V

W

Аьµ¿±в

MIN

MAX

Freq.

P1(FX)-CM

ON

OFF

10 Hz

Wiring Operating

pattern

40

Advertising