LG C Series User Manual

Page 43

Advertising
background image

Chapter 7. Function list

CHAPTER 7 -

Function list

Drive Group

LED

display

Parameter

name

Min/Max

range

Description

Factory

defaults

Adjustable

during run

Page

0.0

[Frequency
command]

0/400
[Hz]

ƒ

This parameter sets the frequency that

the inverter is commanded to output.

ƒ

During Stop: Frequency Command

ƒ

During Run: Output Frequency

ƒ

During Multi-step operation: Multi-step

frequency 0.

ƒ

It cannot be set greater than F21- [Max

frequency].

0.0 O

9-1

ACC [Accel

time]

5.0

O 9-10

dEC [Decel

time]

0/6000
[sec]

ƒ

During Multi-Accel/Decel operation, this

parameter serves as Accel/Decel time 0.

10.0 O

9-10

0

Run/Stop via Run/Stop key on the
keypad

9-7

1

FX: Motor forward run
RX: Motor reverse run

2

Run/Stop
via control
terminal

FX: Run/Stop enable
RX: Reverse rotation select

9-7

Drv [Drive

mode]

(Run/Stop
mode)

0/3

3

Operation via Communication Option

1 X

0

Setting via Keypad 1

9-1

1

Digital

Setting via Keypad 2

9-1

2

Setting via potentiometer on
the keypad (V0)

9-2

3

Setting via V1 terminal

9-3

4

Setting via I terminal

9-3

5

Setting via potentiometer on
the keypad + I terminal

9-4

6

Setting via V1 + I terminal

9-4

7

Setting via potentiometer on
the keypad + V1 terminal

9-5

Frq [Frequency

mode]

0/8

8

Analog

Modbus-RTU
Communication

0 X

St1 [Multi-Step

frequency 1]

This parameter sets Multi-Step frequency 1
during Multi-step operation.

10.0 O

9-6

St2 [Multi-Step

frequency 2]

This parameter sets Multi-Step frequency 2
during Multi-step operation.

20.0 O

9-6

St3 [Multi-Step

frequency 3]

0/400
[Hz]

This parameter sets Multi-Step frequency 3
during Multi-step operation.

30.0 O

9-6

CUr [Output

current]

This parameter displays the output current to
the motor.

- -

11-1

rPM

[Motor RPM]

This parameter displays the number of Motor
RPM.

- -

11-1

dCL [Inverter

DC

link voltage]

This parameter displays DC link voltage inside
the inverter.

- -

11-1

This parameter displays the item selected at
H73- [Monitoring item select].
vOL Output

voltage

POr Output

power

vOL [User

display

select]

tOr Torque

vOL -

11-2

nOn

[Fault Display]

This parameter displays the types of faults,
frequency and operating status at the time of
the fault

- -

11-2

This parameter sets the direction of motor
rotation when drv - [Drive mode] is set to
either 0 or 1.
F Forward

drC [Direction

of

motor rotation
select]

F/r

r Reverse

F O

9-7