LG C Series User Manual

Page 67

Advertising
background image

Chapter 9. Basic functions

z Run command setting 2 at FX and RX terminals

Group

LED Display

Parameter Name

Set

Value

Min/Max

Range

Factory

Defaults

Unit

Drive
group

drv

[Drive mode]
(Run/Stop mode)

2

0/3 1

I20

[Multi-function input
terminal P1 define]

0 0/24

0

I/O
group

I21

[Multi-function input
terminal P2 define]

1 0/24

1

ƒ Set

the drv to 2.

ƒ Set I20 and I21 to 0 and 1 to use P1 and P2 as FX and RX terminals.
ƒ FX: Run command setting. Motor runs in forward direction when RX terminal (P2) is OFF.
ƒ RX: Direction of motor rotation select. Motor runs in reverse direction when RX terminal (P2) is ON.

FX

RX

Frequency

z FX/RX

Run

Disable

Group

LED Display

Parameter Name

Set

Value

Min/Max

Range

Factory

Defaults

Unit

Drive

group

drC

[Direction of motor
rotation select]

- F/r F

Function

group 1

F 1

[Forward/Reverse run
disable]

-

0/2 0

Select the direction of motor rotation.
ƒ 0: Forward and Reverse run enable
ƒ 1: Forward run disable
ƒ 2: Reverse run disable

67