9.7

Frequency limit setting

z Frequency limit setting based on Max and start frequency

Group

LED display

Parameter name

Set

value

Min/Max

range

Factory

defaults

Unit

F21

[Max frequency]

- 0/400 60.0

Hz

Function
group 1

F23

[Start frequency]

- 0/10 0.5

Hz

ƒ Max frequency: Frequency high limit except for F22 [Base frequency]. Any frequency cannot be set

above [Max frequency].

ƒ Start frequency: Frequency low limit. If a frequency is set lower than this, 0.00 is automatically set.


z Run frequency limit based on frequency High/Low limit

Group

LED Display

Parameter Name

Set

Value

Min/Max

Range

Factory

Defaults

Unit

F24

[Frequency High/Low
limit select]

1

0/1 0

F25

[Frequency high limit]

-

0/400

60.0

Hz

Function
group 1

F26

[Frequency low limit]

-

0/400

0.5

Hz

ƒ Set F24 to 1.
ƒ Active run frequency can be set within the range set in F25 and F26.



When frequency setting is done via Analog input (voltage or current input), the inverter

operates within the range of high and low limit frequency as shown below.



This setting is also valid when frequency setting is done via keypad.








Freq.

V1(Voltage input)

Max freq.

0

20mA

10V

I (Current input)

High limit

freq.

Low limit

freq.

When freq. limit is not
selected