LG C Series User Manual

Page 84

Advertising
background image

Chapter 10. Advanced functions

10.5 Dwell operation

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

H 7

[Dwell frequency]

-

0/400 5.0

Hz

Function
group 2

H 8

[Dwell time]

-

0/10 0.0

sec

ƒ In this setting, motor begins to accelerate after dwell operation is executed for dwell time at the

dwell frequency.

ƒ It is mainly used to release mechanical brake in elevators after operating at dwell frequency.



Dwell frequency: This function is used to output torque in an intended direction. It is

useful in hoisting applications to get enough torque before releasing a mechanical brake.

Rated Slip frequency is calculated by the formula shown below.

×

=

120

P

rpm

f

f

r

s

Where,

= Rated slip frequency

s

f

= Rated frequency

r

f

= Motor nameplate RPM

rpm

P = Number of Motor poles

Example

Rated frequency = 60Hz

Rated RPM = 1740rpm

Number of motor poles= 4

Hz

f

s

2

120

4

1740

60

=

×

=

Frequency

Run
command

Dwell time

Dwell freq.

Start freq.

84

Advertising