LG C Series User Manual

Page 92

Advertising
background image

10. Advanced functions

10.11 Speed Search

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

H22

[Speed Search Select]

-

0/15 0

H23

[Current level during
Speed search]

- 80/200 100 %

H24

[P gain during Speed
search]

- 100

Function
group 2

H25

[I gain during speed
search]

-

0/9999

1000

I54

[Multi-function output
terminal select]

15 12

I/O group

I55

[Multi-function relay
select]

15

0/20

17

ƒ This is used to prevent possible fault from occurring if the inverter outputs the output voltage during

operation after the load is removed.

ƒ The inverter estimates the motor rpm based on output current, so detecting exact speed is difficult.



The following table shows 4 types of Speed search selection.

Speed search
during H20 –
[Power ON
start]

Speed search
during Instant
Power Failure
restart

Speed search
during H21-
[Restart after
fault reset]

Speed search
during
Acceleration

Bit 3

Bit 2

Bit 1

Bit 0

0 -

-

-

-

1 -

-

-

9

2 -

-

9

-

3 -

-

9

9

4 -

9

- -

5 -

9

-

9

6 -

9

9

-

7 -

9

9

9

8

9

- - -

9

9

- - 9

10

9

-

9

-

11

9

-

9

9

12

9

9

- -

13

9

9

-

9

14

9

9

9

-

H22 [Speed

search

select]

15

9

9

9

9

92

Advertising