LG C Series User Manual

Page 97

Advertising
background image

10. Advanced functions

z Password

Register

Group

LED Display

Parameter Name

Set

value

Min/Max

Range

Factory

Defaults

Unit

Function
group 2

H94

[Password Register]

-

0/FFF 0

H95

[Parameter lock]

-

0/FFF 0

ƒ This parameter creates password for H95 – [Parameter lock].
ƒ Valid password is Hex decimal value (0-9, A, B, C, D, E, F).

CAUTION:

Do not forget the registered password. It is also used when unlocking the parameters.



Factory default password is 0. Enter the new password except 0.



Follow the table below to register password for Parameter lock.

Step Description

LED

Display

1

Jump to H94 – [Password Register].

H94

2

Press the Prog/Ent (

z) key twice.

0

3

Enter the password you wish (e.g.: 123).

123

4

“123” is blinking by pressing the Prog/Ent (

z) key.

123

4

Press the Prog/Ent (

z) key once to enter the value into memory.

H94



Follow the table below to change the password. (Current PW: 123 -> New PW: 456)

Step Description

LED

Display

1

Jump to H94 – [Password Register].

H94

2

Press the Prog/Ent (

z) key once.

0

3

Enter any number (e.g.: 122)

122

4

Press the Prog/Ent (

z) key. 0 is displayed because wrong value

was entered. Password cannot be changed in this status.

0

5

Enter the right password.

123

6

Press the Prog/Ent (

z) key once.

123

7

Enter a new password.

456

8

Press the Prog/Ent (

z) key. Then “456” will blink.

456

9

Enter the Prog/Ent (

z) key to finish.

H94

97