3 offset chimney installaton – LG P1BRENTW-A User Manual

Page 27

Advertising
background image

25

4.3 OFFSET

CHIMNEY

INSTALLATON

The minimum chimney height when using elbows is:

Fireplace model

BRENTWOOD

Chimney model

AC

Vertical installation

12 ft. (3.66 m)

Two (2) elbows

15 ft. (4.57 m)

Four (4) elbows

17 ft. (5.18 m)

Table 3

After reaching the location requiring the elbow, proceed as follows:

AC Chimney

1. Install the first elbow. Turn it in the required direction. To lock it in place, turn 1/8 of a turn.

Fasten the straps attached to the elbow to the surrounding frame, using nails or drywall
screws.

2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney

lengths together. If penetrating a wall, use a wall radiation shield.

3. Use another elbow to turn the chimney vertically. Lock it to the chimney. Fasten the straps

attached to the elbow to the surrounding framing using nails or drywall screws.

4. Use a plumb bob to line up the centre of the hole. Cut a hole for the chimney in the ceiling.

Frame this hole as described previously.

5. From below, install a firestop. (see figure 23).
6. Continue with the regular installation.


Figure 27

Advertising