Operation, Warning general description – Lincoln Electric INVERTEC V350-PRO IM708 User Manual

Page 14

Advertising
background image

B-1

OPERATION

V350-PRO (CE)

B-1

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or

electrode with skin or wet clothing.

Insulate yourself from work and

ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------

FUMES AND GASES can be danger-
ous.

Keep your head out of fumes.

Use ventilation or exhaust to remove

fumes from breathing zone.

------------------------------------------------------------------------

WELDING SPARKS can cause fire or
explosion.

Keep flammable material away.

Do not weld on closed containers.

------------------------------------------------------------------------

ARC RAYS can burn eyes and skin.

Wear eye, ear and body

protection.

------------------------------------------------------------

See additional warning information at

front of this operator

s manual.

-----------------------------------------------------------

WARNING

GENERAL DESCRIPTION

PRODUCT DESCRIPTION & DUTY CYCLE

The Invertec V350-PRO (CE) offers multi mode CV
and CC DC welding and is rated at 350 amps, 34 volts
at a 60% duty cycle with 3 phase input. It is also rated
at 320 amps with single phase input. It is rated at 275
amps, 100% duty cycle.

OPERATIONAL FEATURES and CONTROLS:

UPPER CONTROL PANEL
1. AMPS Meter

Prior to STICK or TIG operation (current flow), the

meter displays preset current value (either 2 amps
or +/- 3% (e.g. 3 amps on 100), whichever is
greater).

Prior to CV operation, the meter displays four dash-

es indicating non-presettable AMPS.

During welding, this meter displays actual average

amps.

After welding, the meter holds the actual current

value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" char-
acteristics stated above. The displays blink indicat-
ing that the machine is in the "Hold" period.

2. VOLT METER

Prior to CV operation (current flow), the meter dis-

plays desired preset voltage value (+/- .5V).

Prior to STICK or TIG operation, the meter displays

the Open Circuit Voltage of the Power Source or
four dashes if the output has not been turned on.

During welding, this meter displays actual average

volts.

After welding, the meter holds the actual voltage

value for 5 seconds. The displays blink indicating
that the machine is in the "Hold" period.

Output adjustment while in the "hold" period results

in the "prior to operation" characteristics stated
above.

3. OUTPUT CONTROL

Output control is conducted via a single turn poten-

tiometer.

Adjustment is indicated by the meters as stated

above.

When in TIG modes, this control sets the maximum

welding current. Full depression of a foot or hand
Amptrol results in the preset level of current.

4. WELD TERMINALS-REMOTE , ON

Two status lights indicate the location of trigger con-

trol as determined by the "WELD TERMINALS"
push button.

If trigger control is local "weld terminals on", the ON

display will be lit.

If trigger control is remote "weld terminals remotely

controlled", the REMOTE display will be lit.

The unit will power up in "pre-determined preferred"

trigger modes.

STICK = ON
TIG and CV = ON or REMOTE depending if remote
output controls are connected to the machine.

Advertising