Linak TECHLINE LA35 User Manual

Page 13

Advertising
background image

13

I/O Specifi cations: Relative positioning

I/O Specifi cations: Absolute positioning

Item

Specifi cation

Comment

Description

The actuator can be equipped with a hall
sensor and a spindle magnet. In this way
you can have pulses from the actuator
when it moves. The output signal is a PNP
signal.

Input Voltage

10-28 V DC

Feedback circuit to be powered 1second
before motor runs, and until 1 second
after the motor has stopped.
Cable dimension 6 x 0.5 mm

2

(6 x AWG20)

Output voltage

Same as input voltage

Typical Output voltage:
HIGH: Output = Input -1V (+/- 0.5V)
LOW: Output = 0-0.5V

Current consumption

Current consumption is max. 40 mA

Also when actuator is not running

Switching capacity

100 mA, max.

Resolution

The feedback system gives 8 pulses per
spindle turn:
3 mm pitch = 0.38 mm per pulse
5 mm pitch = 0.63 mm per pulse
9 mm pitch = 1.13 mm per pulse
12 mm pitch = 1.5 mm per pulse

Pulse/pause minimum 10 Milliseconds.
On 100 mm stroke you will have the fol-
lowing number of pulses:
3 mm pitch = 266 pulses
5 mm pitch = 160 pulses
9 mm pitch = 88 pulses
12 mm pitch = 66 pulses

Connection

Supply: White (Pin 3)
Ground: Black (Pin 1)
Signal: Violet (Pin 4)

See fi gure 3
Use cable 0367003-XXXX

Combinations

The Relative positioning can be combined
with potential free
Switches. But cannot be combined with
absolute positioning

35xxxxxxHxxxxx

Item

Specifi cation

Comment

Description

The actuator can be equipped with
electronic circuit that gives an analog
feedback signal when the actuator moves.

Input Voltage

11-28 V DC

Feedback circuit to be powered 1 second
before motor runs, and until 1 second
after the motor has stopped.
Cable dimension 6 x 0,5 mm

2

(6 x AWG20)

Output voltage

0 -10V
0V = Fully retracted
10V = Fully extended

+/- 0.5V

Current consumption

Current consumption is max. 40 mA

Also when actuator is not running

Connection

Supply: White (Pin 3)
Ground: Black (Pin 1)
Signal: Violet (Pin 4)

See fi gure 4
Use cable 0367003-XXXX

Combinations

The Absolute positioning can be combined
with potential free Switches. But cannot
be combined with relative positioning

35xxxxxxAxxxxx