Lochinvar KBN-SUB-09 User Manual

Knight heating boiler submittal sheet kbn-sub-09

Advertising
background image

KNIGHT

®

FLOOR STANDING AND WALL MOUNT HEATING BOILERS

KNIGHT

HEATING BOILER

Submittal Sheet

KBN-Sub-09

JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
Btu/hr OUTPUT___________________________________________________________________
NOTES

Standard Features

>Energy Star

®

Qualified

> Up to 96% DOE AFUE Efficiency
> Modulating Burner with 5:1 Turndown
> Direct-Spark Ignition
> Low NOx Operation
> Field Convertible from Natural to LP Gas
> Vertical & Horizontal Direct-Vent
> PVC, CPVC or SS Venting up to 100 Feet
> Factory Supplied Sidewall Vent Termination
> ASME Stainless Steel Heat Exchanger
> Automatic Reset High Limit
> Inlet & Outlet Temperature Sensors
> Boiler Circulating Pump
> 30 psi ASME Relief Valve
> Adjustable Leveling Legs (KB Models only)
> Wall Mount Bracket (WB Models only)
> Zero Clearances to Combustible Material
> 12 Year Limited Warranty (See Warranty for Details)
SMART SYSTEM

TM

Features

> SMART SYSTEM Digital Operating Control
> 2 line, 16 Character Display
> Dual Level Password Security
> Domestic Hot Water Prioritization
> Built in Cascading Sequencer for up to 8 Boilers
> 0-10 VDC Input Control
> Outdoor Reset Control with Outdoor Air Sensor
> Low Water Flow Safety Control & Indication
> Alarm on Any Failure Contacts
> Service Reminder
> Freeze Protection
> Night Setback
> Time Clock
> Three Pump Control (System, Boiler & DHWP)
> Data Logging

> Examples: Hours Running, Space Heating

> Programmable System Efficiency Optimizers

> Examples: Anti-cycling, Ramp Delay

Optional Equipment

Place an X in the box by all options that apply

Adjustable High Limit w/ Manual Reset

Flow Switch

Low Water Cutoff w/Manual Reset & Test

Alarm Bell

Concentric Vent Kit

Condensate Neutralization Kit

SMART SYSTEM PC Software

Multi-Stack Frame

Firing Codes

M9 Standard Construction

M7 California Code

Advertising