NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Note: Hearth protection to be min. 3/8” (10mm) thick non-
combustible or equivalent, with a k factor of .84.

i

nsert

l

eveling

At each front and rear corner of the insert is an adjustable leg

provided to level the insert should the hearth of the fireplace

be uneven. To adjust the legs, loosen the two 5/32" allen head

screws, move the leg to the desired height, and then tighten

the screws. Repeat these steps for each adjusting leg.

RDV40

G

14”(356mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

IMPORTANT: If unit is converted to an RDV33 from an

RDV40, the clearances to combustibles can be reduced

as shown on this page.
WARNING: If this unit is ever converted back to an RDV40,

ensure that the clearances are correct for this model.

RDV33

G

13”(330mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

E

H

F

G

J

CL

MANTEL

TRIM

Mantel

Trim

Hearth / Floor Protection

Minimum clearances include any projections such as

shelves, window sills, mantels, spacers/standoffs or

surfaces to combustible construction etc. above the ap-

pliance. Paint or lacquer used to finish the mantel must

be heat resistant in order to avoid discoloration.

The letters below, E through J, correspond to Figure 5

showing minimum clearances required from the appliance

to combustibles and the minimum projection of the hearth

extension.

E = From Top Facing or Mantel to Bottom of Insert -

.2

RDV40 = 35-1/2”(902mm) and RDV33 = 31-

1/2”(800mm)

F = 25-1/2" From Center of Glass Door to Side Facing or

Wall - RDV40 = 25.5”(648mm) and RDV33 = 25.5”

(648mm)

J = 10.5” (267mm) Mantel to Bottom of Insert -

.2

RDV40 = 43”(1092mm) and RDV33 = 39”(991mm)

h

earth

p

roteCtion

G = Minimum Hearth Protection from Front of Insert*

H = Vertical Distance from Insert Bottom to Combustible

Material.

Clearances to Combustibles

m

inimum

C

learanCes

to

C

ombustibles

Figure 4A

Figure 5 - Clearances

RDV40

Facing &

Mantel -

Side View

f

aCing

and

m

antel

C

learanCes

Please note that the RDV33 mantel clearances are 4" less than the RDV40

mantel clearances as shown in Figures 4A (RDV40) and 4B (RDV33).

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

35-1/2”

902mm

37-1/2”

953mm

40-1/2”

1029mm

43-1/2”

1105mm

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

31-1/2”

800mm

33-1/2”

851mm

36-1/2”

927mm

39-1/2”

1003mm

RDV33

Facing &

Mantel -

Side View

Figure 4B

Advertising