INSTALLATION

See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.

PAGE 13

SINGLE WALL PIPE

Using 6” Diameter Single Wall Connector Pipe

DOUBLE WALL PIPE

(Approved for Model CI2000HT Only)

Using 6” Diameter Type L-Vent Connector Pipe

IMPORTANT NOTES:

Minimize the use of elbows (30

°, 45° or 90°) - Offsets in the

venting system are very restrictive and will inhibit the draft
(i.e. You will lose approximately 5 feet of effective draft for
every 90 degrees of direction change). This appliance re-
quires 12 to 15 feet of effective draft for optimum perform-
ance (see Draft Requirements
on page 12).

First section of pipe must be vertical - Use as much straight
vertical pipe directly above the appliance as possible be-
fore using an elbow (a 2’ to 3’ initial vertical rise is sug-
gested).

Chimney
Termination
Cap

Ceiling Support
Assembly

Storm
Collar

Roof
Flashing

Slip
Adapter

Minimum of 12-15' of
Flue to achieve a
stable draft

.

Chimney
Connector

6" x 24" 24-gage
black steel or 26 gage
blued steel single wall
pipe

7 Feet
Minimum

DVL Close
Clearance
Connector
Pipe

Floor
Protector

Support
Box

3 Feet

Minimum

Termination
Cap with
Spark Arrestor

Storm Collar

Flashing