PLANNING YOUR INSTALLATION

– Model CI1000HT

PAGE 8

MODEL CI1000HT
COMBUSTIBLE WALL CLEARANCE – USA & Canada

WARNING: It is very important that you observe the
minimum clearances.

There are listed clearances for your stove which were
determined in a Laboratory test using various "classes"
of stove pipe or chimney. Minimums are first estab-
lished for the stove itself and increased based on how
much heat is transferred by each class of pipe.

Position the unit no closer than the minimum clearances
to combustible materials. Check that no overhead
cross members in the ceiling or roof will be cut. Repo-
sition unit if necessary being careful not to move closer
than the minimum clearances.

Minimum Ceiling Height – 7 feet / 2133mm from floor
to ceiling.

SINGLE WALL PIPE WITHOUT PIPE SHIELD
Using single wall 24 MSG black or 25 MSG blued steel
connector pipe with factory-built chimney listed to either
UL 103HT or ULC S629.

Minimum Clearances (inches)
A.

27 1/2" / 699mm D. 24" / 610mm

B. 27" / 686mm E. 18" / 457mm
C. 27" / 686mm F. 19" / 483mm

G. 35 3/16” / 894 mm (this is a reference dimension only)

SINGLE WALL PIPE WITH PIPE SHIELD / REDUCED
CLEARANCE

Using single wall 24 MSG black or 25 MSG blued steel
connector pipe with factory-built chimney listed to either
UL 103HT or ULC S629. The use of a pipe shield for 6"
connector with 1" clearance to the pipe is mandatory.

Minimum Clearances (Inches)
A. 21 1/2" / 546mm D. 18" / 457 mm
B. 27" / 686mm

E. 18" / 457mm

C. 19" / 483mm

F. 11" / 279mm


G. 23 7/8” / 606 mm (this is a reference dimension only)


PROTECTED WALL CLEARANCE

Some local codes will allow reduced clearances when the
stove is installed adjacent to a protected wall system. The
variance must be approved by your local building official.
Normally, the protected wall system is defined as a non-
combustible material with a minimum of 1" air space be-
hind. Check your local building codes or with a qualified
installer (Ref. NFPA 211).

Parallel Installation




Corner Installation


MODEL CI1000HT IS NOT APPROVED FOR USE

WITH DOUBLE WALL PIPE.


DO NOT INSTALL THE CI1000HT INTO AN AL-

COVE OR A CONFINED SPACE. This unit has
not been tested or approved for installation into
a confined space such as an alcove (see the na-
tional standard below).

NFPA 211-96, 9-2.2: (Applies to Solid Fuel Burn-
ing Appliances
, which are not alcove tested) -
Solid fuel-burning appliances shall not be in-
stalled in confined spaces. The space or room
shall be of ample size to allow adequate circula-
tion of heated air. Appliances shall be so lo-
cated as not to interfere with the proper circula-
tion of air within the heated space.

A

D

B

E

F

C

G