XR-16

X

TENDED RANGE

SIXTEEN CHANNEL
SUPERVISED
STATIONARY
RECEIVER

For Use With
Linear’s XR Series
Xtended Range
Transmitters

Installation
Instructions

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

1.

PRODUCT DESCRIPTION

Linear’s Xtended Range FM receivers and transmitters are designed for use in various
wireless remote control applications. When the Model XR-16 receiver detects a signal
from its companion transmitters, it will verify the digital code, activate the correct output
channel, and trigger the remote device connected to the receiver.

The XR-16 receiver has full supervision capabilities. If the “status” option for a channel
is selected, the receiver expects hourly status signals from that channel’s transmitter.
If these signals cease, the receiver will indicate trouble by activating its status output
after four hours. Contact supervision allows the receiver’s outputs to follow the
transmitter’s inputs, each output staying activated as long as each transmitter input is
activated. Alternately, an “auto-restore” option can be selected in the transmitter,
causing a momentary receiver output each time any transmitter input is activated. If
the transmitter sends a low battery signal, the receiver’s low battery output will activate.

Power for the XR-16 receiver can come from an external 12 VDC power supply (Linear
Model T-1224DC) or from a 12-volt battery. A diode protects the unit from reverse
power polarity. The XR-16 draws about 50 mA standby, and about 350 mA when all
outputs are active. The alarm, low battery and status outputs are solid state and are
capable of switching up to 100 mA @ 24 VDC to ground (programmable as N/O or
N/C). The receiver’s relay can activate with all signals, or just alarm signals. It provides
isolated N/O and N/C relay contacts capable of switching a maximum of 1 Amp @
24 VDC.

Two antennas (sold separately) are available for the XR-16. The Model ANT-1A is an
8-inch “rubber duck” antenna for short range applications (less than 1 mile). The ANT-1
requires a Model CON-180A connector to mate the antenna to the receiver. The Model
ANT-2 is a 3-foot whip antenna for use in long range or difficult installations where more
range from the XR-16 is required. A common 9-foot 1/4 wave CB whip antenna can
also be used with the XR-16 for maximum range.

Two 8-position switches set the unit’s system code. This code must be matched in the
XR-16’s transmitters. There are 65,536 different system codes possible. The two
8-position option switches select the status supervision option for each of the
16 channels.

The receiver is housed in a metal enclosure with an SO-239 antenna connector. Three
displays are visible through a window on the case. The left two displays show the
channel number, the right display shows the condition. The display scrolls through all
the channel numbers with a condition. The right decimal point lights when the receiver
has power. During reception, the center decimal point lights. Two internal test points
are provided for signal strength and audio monitoring.

2.

SYSTEM OVERVIEW

3.

DISPLAYED CONDITIONS

4.

COMPONENT LOCATIONS

5.

MOUNT RECEIVER

6.

CONNECT ANTENNA

7.

TERMINAL BLOCK DETAILS

WARNING: THIS

PRODUCT SHOULD NOT

BE USED IN LIFE

SAFETY APPLICATIONS.

FCC Rules allow

unlicensed high-power

transmissions at or near

the operating frequency

of this product which
may interfere with, or

even disable, normal

operation of this radio

device.

XR-16 RECEIVER

CONTROL PANEL

EXAMPLE

TRANSMITTERS

MODEL

XT-1

MODEL

XT-4

AN UNLIMITED NUMBER
OF TRANSMITTERS CAN
BE USED WITH THE XR-16

16 CHANNEL
OUTPUT

CONDITIONS FOR ALL TRANSMITTERS

ROTATE ON THE DISPLAY

TRANSMITTER ALARM

TRANSMITTERS WILL CAUSE THIS CONDITION WHEN THEY SEND A
VIOLATION SIGNAL. THE CONDITION WILL REMAIN UNTIL A RESTORE
SIGNAL IS SENT, UNLESS THE TRANSMITTER IS SET AS "AUTO
RESTORE". THE TRANSMITTER'S CHANNEL OUTPUT WILL BE FAULTED
AS LONG AS THIS CONDITION IS DISPLAYED.

ANY TRANSMITTER SENDING A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION. DISPLAY WILL REMAIN UNTIL A SIGNAL OCCURS FROM THE
SAME TRANSMITTER WITH A GOOD BATTERY.

TRANSMITTER LOW BATTERY

EACH RECEIVER CHANNEL CAN BE SET AS SUPERVISED OR NON-
SUPERVISED. IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS
FROM A TRANSMITTER PROGRAMMED TO A SUPERVISED CHANNEL
FOR FOUR HOURS, THIS CONDITION WILL BE DISPLAYED. DISPLAY WILL
CLEAR THE NEXT TIME A SIGNAL IS RECEIVED FROM THE
TRANSMITTER.

TRANSMITTER STATUS ALERT

TRANSMITTER

CONDITION

POWER
INDICATOR

SIGNAL
INDICATOR

DASHES WILL MOVE ACROSS THE

DISPLAY WHILE THE RECEIVER IS IDLE

WIRING
KNOCKOUTS

TEST POINTS

SIGNAL

LEVEL

AUDIO

OUTPUT

GROUND

ANTENNA

CONNECTOR

SYSTEM CODE

SWITCHES "A" & "B"

STATUS OPTION
SWITCHES 1-16

TRANSMITTER
CHANNEL
NUMBER

TRANSMITTER
CONDITION

TERMINAL
BLOCK

OUTPUT
OPTION
JUMPER

RELAY
OPTION
JUMPER

ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS

7"

5-1/8"

5-1/8"

USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER

MOUNTING

PATTERN

USE 3-FOOT LONG ANT-2
ANTENNA FOR LONGER
RANGE APPLICATIONS OR
DIFFICULT INSTALLATIONS

ANT-1A

ANTENNA

USE ANT-1A ANTENNA FOR
SHORT RANGE (LESS THAN
1 MILE) APPLICATIONS

CON-180A
STRAIGHT
CONNECTOR

MOUNT ANTENNA AS HIGH AS POSSIBLE
(A METAL MOUNTING POLE IS
RECOMMENDED)

AN 18-FOOT RG-58 CABLE IS SUPPLIED
WITH THE ANT-2 KIT. UP TO 50 FEET OF
RG-58 CAN BE USED. USE RG-8 FOR UP
TO 100-FOOT CABLE RUNS.

TO XR-16

MOUNT ANTENNAS AS FAR AS POSSIBLE FROM
COMPUTERS TO MINIMIZE INTERFERENCE
GENERATED BY THE COMPUTER

CH1

CH2

CH3

CH4

GND

CH5

CH6

CH7

CH8

GND

CH9

CH10

CH11

CH12

GND

CH13

CH14

XR-16 TERMINALS

RECEIVER CHANNEL OUTPUTS

POWER INPUT

LOW BAT

STS ALM

GND

N/O

N/C

COM

+12 VDC

GND

CH15

CH16

GND

EACH OUTPUT ACTIVATES WHEN ANY TRANSMITTER
PROGRAMMED FOR THAT CHANNEL IS IN THE VIOLATED
(ALARM) CONDITION. REMAINS ACTIVE UNTIL ALL
TRANSMITTERS PROGRAMMED TO THAT CHANNEL ARE
RESTORED AND ALL ALARM INDICATIONS ("A" ON
CONDITION DISPLAY) ARE CLEARED.

IF THE TRANSMITTER IS PROGRAMMED FOR AUTO-
RESTORE, THE OUTPUT WILL BE MOMENTARY,
ACTIVATING FOR ONLY TWO SECONDS.

NOTES:
1. OUTPUTS CAN CONNECT TO ZONE INPUTS ON AN
ALARM CONTROL PANEL OR MANY OTHER TYPES OF
EXTERNAL DEVICES.

2. ALL GND TERMINALS ARE COMMON GROUND AND
CONNECTED TOGETHER.

3. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH
OUTPUT RETURNS TO ANY COM TERMINAL.

4. EACH SOLID STATE OUTPUT CAN SWITCH UP TO
100 mA @ 24 VDC MAXIMUM.

FOR CONNECTION TO A REGULATED DC POWER SOURCE.
THE POWER INPUT CAN BE FROM 11-16 VDC ONLY.

RELAY

DRY CONTACTS, FORM C, 1 AMP @ 24 VDC MAXIMUM
RATING. JUMPER SELECTABLE TO ACTIVATE AS LONG AS
ANY OUTPUT IS ACTIVE, OR AS LONG AS ANY CHANNEL
OUTPUT IS ACTIVE.

RELAY OUTPUT

STATUS OUTPUT

LOW BATTERY OUTPUT

ACTIVATES WHEN ANY CHANNEL PROGRAMMED TO
EXPECT STATUS TRANSMISSIONS DOES NOT RECEIVE ANY
STATUS SIGNALS FOR FOUR HOURS. REMAINS ACTIVE
UNTIL SIGNALS ARE RECEIVED AND ALL STATUS
INDICATIONS ("S" ON CONDITION DISPLAY) ARE CLEARED.

ACTIVATES WHEN ANY TRANSMITTER SENDS A LOW
BATTERY SIGNAL. REMAINS ACTIVE UNTIL A GOOD
BATTERY SIGNAL IS RECEIVED AND ALL LOW BATTERY
INDICATIONS ("L" ON CONDITION DISPLAY) ARE CLEARED.