CHOOSE THE PROPER LOCATION

• Store and install the dryer where it will not be

exposed to temperatures below freezing or
exposed to outdoor weather conditions.

• Choose a location with a solid, level fl oor.

• If the dryer is being installed in a garage,

place the dryer at least 18 in. (46 cm) above
the fl oor.

CLEARANCES

30"

(76.1 cm)

50"

(127 cm)

20"

(50.8 cm)

4"

(10 cm)

18"

(45.72 cm)

4"

(10 cm)

• Most installations require a minimum 5½ in.

(14 cm) clearance behind the dryer for the
exhaust ducting.

• Allow minimum clearances of at least 1 in.

(2.5 cm) on the sides and back to minimize
vibration and noise.

• Allowing additional clearance for installation and

servicing is recommended.

• Be sure to allow for wall, door, or fl oor moldings

that may increase the required clearances.

• Allow at least 24 in. (61 cm) in front of the dryer

to open the door.

IMPORTANT: Read all installation instructions completely before
installing and operating your dryer!

It is important that you review this entire manual before installing and using your dryer. Detailed instructions
concerning electrical connections, gas connections, and exhaust requirements are provided on the
following pages.

• Properly ground dryer to conform with all

governing codes and ordinances.

• To reduce the risk of electric shock, do not

install the dryer in damp or wet locations.

• If you are installing your dryer in a manufactured

or mobile home, please refer to the section
Special Requirements for Manufactured or
Mobile Homes
.

Additional Instructions for closet installations:

• The closet door must allow for suffi cient airfl ow.

Refer to the diagram above for minimum vent
opening requirements. A louvered door is also
acceptable.

• Make sure that there is at least 18 in. (46 cm) of

clearance above the dryer.

27"

(68.6 cm)

1"

(2.54 cm)

1"

(2.54 cm)

24 in.