Electrical installation, Motor – Linak LA36 User Manual

Page 12

Advertising
background image

12

Connection diagrams:

Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxxxx1H/Pxxxxxx

5 K 6

5 K 6

1 0

1 K

1 0 K

0

0

A

B

B r o w n

B l u e

R e d

Y e l l o w

G r e e n

W h i t e

V i o l e t

B l a c k

M o t o r P o w e r + / - ( o u t / i n ) 1 2 V / 2 4 V / 3 6 V

S u p p l y + 1 2 v t o 3 6 V

H a l l A ( E n d I N )

H a l l B ( E n d O U T )

+ 1 0 V e x i t a t i o n

0 - 1 0 V O u t

G N D

P C B : 0 0 L A 3 6 M H P - X - X

+

-

24

V

8 0 m A

S i g n a l s O U T

1 0

1 0

1 0

Electrical installation

Be aware of BUS actuator - please see the separate installation guide.

Motor connection
Wiring: The actuator direction (forward, reverse) is controlled with a doublethrow

switch with the centre postion “off”.

Motor

+

Actuation
To extend the actuator, connect brown to positive and blue to negative.
To retract the actuator, connect blue to positive and brown to negative.