Vertical height (ft), Horizontal distance (ft) – Lennox Hearth EPIC40 User Manual

Page 16

Advertising
background image

6

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

2

4

6

8

10

12

14

16

18

20

2

4

6

8

10

12

14

16

18

20

22

24

26

28

MIN. 24" VERT. PIPE SECT.
WITH 9" HORIZONTAL SECT.

8' MAX

30' MAX

30

19' 7" MAX VERT. WITH

8' HORIZONTAL

VERTICAL HEIGHT (FT)

2

4

6

8

2

4

6

8

VERTICAL HEIGHT (FT)

HORIZONTAL DISTANCE (FT)

HORIZONTAL DISTANCE (FT)

6' MAX

A

B

C

D

RESTRICTOR POSITIONS

’ (MIN) OF

VERTICAL PIPE

REQUIRED

BELOW

TERMINATION

Vertical Terminations

The diagram below shows all allowable combinations of

straight vertical and offset to vertical vent configurations

with vertical terminations. The termination must fall within

the shaded areas on the diagram. Use the restrictor positions

indicated. Offsets may consist of two 90° elbows OR four

45° elbows. The minimum termination height is 10 feet and

the maximum is 30 feet.

NOTE: Horizontal pipe requires 1/4” rise for every 12”

of run. Offsets must remain within max and min lines.

Vertical height is measured from the bottom of stove.

Horizontal Terminations

The shaded areas in the diagram below show all allowable

combinations of vent configurations with horizontal termi-

nations. Horizontal sections of pipe require 1/4” of rise for

every 12” of run. A second 90° or 45° elbow (in addition to

the first 90° elbow at the top of the vertical length of pipe)

is allowed as long as the overall length of the horizontal

run of pipe does not exceed those shown below. Use the

restrictor positions indicated. Note that if the termination

cap falls in the unshaded area, then no restrictor is installed

in the stove.

Figure 25

Figure 26