6

WARNING

When using a gas burner, it is

mandatory to keep the chimney

outside air register opened.

WARNING

Do not place loose insulation or

any other material in the space

around the fireplace or the

chimney. Insulation placed on

or around the fireplace or chim-

ney may cause adjacent wood to

overheat and catch on fire.

Failure to use LHP parts or conduct variations

in techniques and construction materials

described in this installation manual may

create a serious fire hazard and may void

the warranty and the WHI listing.

3. Always check your local building codes.

The installation must comply with their

regulations. Before beginning the instal-

lation, consult the local authorities and

make sure your building permit complies

with their requirements.

4. This fireplace must be installed with Security

Chimneys™ chimney system models ASHT+,

S-2100+ or AC, of 8" inside diameter. These

systems are intended for use in any applica-

tion where a traditional masonry type fireplace

would apply. The chimney system must

always vent to the outside of the building.

5. To maintain top efficiency and to prevent

build-up of soot and creosote, inspect and

clean the chimney periodically during the

heating season.

6. To prevent possible hazards due to poor

combustion and to avoid affecting other fuel

burning appliances (furnace, wood stove,

etc.), ensure that the outside air kit is properly

installed.

7. This fireplace is designed to allow the instal-

lation of a gas burner. In such a case, the

installation must conform with the National

Gas Code ANSI Z223.1 and Z21.60.

Tools And Building Supplies Normally

Required

Tools:
Phillips screwdriver

Slot style screwdriver

Hammer

Saw and/or Sabersaw

Level

Measuring tape

Plumb line

Electric drill and bits

Pliers

Square

If gas pipe is used:
Pipe wrench

Pipe cutter

Pipe threader

Pipe joint compound

Pipe key valve

Building supplies:
2" x 3" or heavier lumber

Drywall panel or equivalent

Silicone caulking (non-combustible)

Overlay material for fireplace façade

Hearth extension (non-combustible)

PRECAUTIONS!

The most important areas of concern dealing

with the fireplace installation are clearances

to combustible materials, secure assembly of

components parts, the height of the chimney

system, the proper use of accessory equip-

ment and the techniques used in using finish-

ing materials applied to fireplace surrounds,

hearth extensions and wall coverings. Each

of these topics will be covered in greater detail

throughout this manual. Please give special

attention to these instructions as you progress

with your installation.

Fireplace Installation Procedure

1. Move the fireplace into the desired position

(follow the recommendations below for

enclosure).

2. Install the outside air assembly (or assem-

blies) - refer to Page 8.

3. Install the enclosure surrounding the fire-

place (refer to the sections “Enclosure” below

and “ Facing and Mantel” on Page 7).

4. Install the hearth extension (see Page 8).

Make sure the gap between the fireplace

and the hearth extension is sealed.

8. This fireplace has provision for the installa-

tion of a gas pipe and is intended only for

connection to a decorative gas appliance

incorporating an automatic shutoff device

and complying with ANSI Z21.60-M96/CGA

2.26-M96, Standard for Decorative Gas Ap-

pliances for Installation in Solid-Fuel Burning

Fireplaces (reference Clause 4.1.3 T).

9. The ME43 fireplaces are sold with factory

installed doors. The outside combustion

air kit is mandatory and is included with the

fireplace. Optional blowers and decorative

trims are available.

LOCATING THE LENNOX FIREPLACE

Do not place the fireplace on carpeting, vinyl

or other soft surface floor coverings. It may,

however, be directly placed on flat wood,

plywood, particle board or other hard surface

materials.

ADjACENT WALL

A wall perpendicular to and in front of the fire-

place front facing must be at least 18" (460mm)

from the fireplace opening. A wall at 45º to the

front facing and starting at the fireplace’s outer

edge is permitted. Projections within this area

are permitted. See Figure 4.

Figure 4

1. The fireplace must be installed against a

finished wall (like drywall finish). It must

not be installed against a vapor barrier or

exposed insulation (see Figure 5).

2. Combustible materials like wood, plywood,

particle board or drywall can be in direct

contact with the fireplace standoffs. Two

inch (50mm) clearance to combustibles

must be kept around the chimney.

ENCLOSURE

OPENING

WALL

FIREPLACE

STANDOFFS

18"

(460mm)

45°