NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

9

INSTALLATION OF THE FAN KIT MODEL

UZY3

Note: This fan kit can easily be installed when

the fireplace has a pre-installed junction box.

You just have to plug them in.

Rating: 120 Volts, 60Hz, .63A.

The fans have magnetic blower mounts. The

junction box (factory installed on approved

fireplaces for the use of this fan kit) must be

connected to 110 VAC service before perma-

nently enclosing the fireplace. The access hole

for connecting the 110 VAC is located on the

lower right exterior side of the fireplace.

Installation instructions:

1. Open the bottom louver of the fireplace.

2. Place each fan kit into the fireplace side

opening 1" from the back of the fire-

place.

3. Install the automatic fan activator on the

side of the firebox (the fan activator has

a magnetic mount).

4. Plug the fan kit into the junction box.

5. Ground both fans to the back panel using

the green screws (see Figure 9).

Figure 9

ELECTRICAL CONNECTION

WITH

GROUND CONNECTION

THERMODISC, AUTOMATIC

THERMAL FAN ACTIVATOR

CONNECTOR FOR

OPTIONAL RHEOSTAT

FAN WITH

MAGNET

FAN WITH

MAGNET

NOTE: The fireplace must be electrically connected and grounded in accordance with local codes

or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For U.S.A.

installations, follow local codes and the National Electrical Code ANSI/NFPA No 70.

CAUTION: SHOULD THIS FAN REqUIRE SERVICING, THE POWER SUPPLY MUST BE DISCON-

NECTED.

These fans require periodic maintenance. Check the area in front of the fans and wipe or vacuum

at least once a month during the burn season.