DLP Personal Projector

Operative Information

When the three LEDs light up, they indicate the power, lamp or internal
temperature status or possible problems:

LED Indicator LEDs Display

Description

Power
Indicator

Orange

Standby (The AC power switch is on,
and the projector is off.)

Blinking Green

When the power button is pressed, the
indicator blinks green until the LG logo
shows up.

Green

The projector is working,

Blinking Orange

POWER-DOWN. It will cools down for
90 seconds after the power is turned off.

-

Off (The AC power switch is off.)

Lamp
Indicator

Orange

The lamp has been in operation for over
1400 hours. The OSD message
“CHANGE LAMP, AND RESET LAMP
TIMER.” will be displayed on the screen
for 30 seconds.

Red

The lamp has been in operation for over
1500 hours. The OSD message “OUT
OF LAMP USAGE TIME. CHANGE THE
LAMP!” will be displayed on the screen
for 30 seconds.

Blinking Red

Something is wrong with the lamp power
supply. Please turn off the projector
within 3 seconds.

Temperature
Indicator

Red

The internal temperature of the projector
is too hot.
When the temperature inside the
projector is too high, the OSD message
“Temperature is too high. Going to shut
down.” will be displayed on the screen
for 10 seconds and then the projector
will automatically shutdown. The fans
will be continuing to run for 90 seconds,
then you can restart the projector.

Blinking Red

Something is wrong with the fans. The
OSD message “Fan or Diode error.
Going to shut down.” will be displayed
on the screen for 10 seconds, and then
the projector will automatically
shutdown. Please turn the projector off.