INSTR,INST,WOR
Linear P/N: 212902 C
Material: 20 Lb. Mead Bond
Size: 8.500" x 11.000"
Ink: Black
Side 1 of 2
Scale: 1-1

WOR

Wiegand
Output
Receiver

Installation
Instructions

INTRODUCTION

The Model WOR remote radio receiver is designed for use as an access control interface for Linear’s block coded
digital transmitters. The unit receives signals from transmitters, adds a facility code to the data, and sends the
information to the Wiegand input of the access control panel via a 5-wire connection.

Several transmitter and receiver options can be set using the unit’s dipswitches. Three different Wiegand output
formats (26, 30, & 31-bit) are supported. Three receiver options (lockout, hold, & button offset) can be set.
Transmitter buttons on multi-button units can be selectively disabled. The facility code is set using 16 dipswitches.

Three antenna types can be used with this receiver. The local whip antenna (supplied) screws directly on to the
receiver. The directional (EXA-2000) and omni-directional (EXA-1000) remote antennas attach to the receiver’s
antenna input via RG-59 cable and a type “F” connector.

An on-board RADIO RANGE knob allows adjustment of the receiver’s gain. It can be set to limit the maximum
radio range that the receiver can achieve. Two indicators display the receivers performance and operation. The
red RADIO indicator lights when the receiver detects a radio signal. The two color red/green STATUS indicator
lights green when the receiver is sending Wiegand data and during the 1-second post receiver lockout timer (if
receiver lockout is enabled). The indicator turns red when the receiver’s HOLD input (connected to the access
control panel) is active. Receiver test points are provided for listening to the incoming signals with an audio
amplifier.

Power input to the receiver can be either regulated 5 volts or 8-24 volts DC (jumper selected).

The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and
a weather-tight wiring strain relief seal the unit from the elements.

1.

OPEN CASE

2.

LOCATE COMPONENTS

3.

SET VOLTAGE INPUT JUMPER

4.

SET OUTPUT FORMAT & RECEIVER OPTIONS

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

OPEN CASE FROM
ANTENNA END

REMOVE FOUR
SCREWS AND WASHERS

BOARD SLIDES OUT
FROM 3RD SLOT UP
INSIDE CASE

5.

SET TRANSMITTER FACILITY CODE

6.

SET TRANSMITTER BUTTON OPTIONS

ANTENNA
CONNECTOR
(HIDDEN)

RADIO RANGE KNOB
(CLOCKWISE FOR
MAXIMUM GAIN)

MAX

RADIO
TEST POINTS

GND

AUDIO

RADIO INDICATOR

STATUS INDICATOR
RED = HOLD, GREEN = DECODE

POWER AND
DATA TERMINALS

OPTION
DIPSWITCHES

INPUT
VOLTAGE
JUMPER

PROGRAM
BUTTON

PLACE VOLTAGE INPUT JUMPER
IN THIS POSITION TO SELECT A
REGULATED 5 VOLT DC INPUT
FROM THE ACCESS CONTROL
PANEL

PLACE VOLTAGE INPUT JUMPER
IN THIS POSITION TO SELECT A
8-24 VOLT DC INPUT FROM THE
ACCESS CONTROL PANEL

SELECT THE WIEGAND OUTPUT FORMAT
THAT MATCHES THE ACCESS CONTROL
SYSTEM BEING USED

SWITCH 1 26-BIT
SWITCH 2 30-BIT
SWITCH 3 31-BIT

RECEIVER OPTIONS

WIEGAND OUTPUT FORMAT

SWITCH 1 - LOCKOUT DISABLE

SWITCH 2 - HOLD ENABLE

SWITCH 3 - BUTTON OFFSET ENABLE

OFF

- (FACTORY SETTING) CAUSES RECEIVER TO IGNORE TRANSMITTER SIGNALS FOR ONE SECOND AFTER A VALIDATED TRANSMISSION.

ON

- ALLOWS RECEIVER TO PASS WIEGAND DATA INSTANTLY WITH EACH VALIDATED TRANSMISSION.

OFF

- (FACTORY SETTING) HOLD INPUT SIGNALS ARE IGNORED.

ON

- WHEN HOLD INPUT IS ACTIVE, ANY WIEGAND DATA WILL BE HELD FOR A MAXIMUM OF ONE SECOND THEN DISCARDED UNLESS THE

HOLD INPUT IS RELEASED DURING THE ONE SECOND TIME.

OFF

- (FACTORY SETTING) TRANSMITTERS PASS THEIR ID NUMBER TO THE WIEGAND OUTPUT WITHOUT ANY CHANGES.

ON

- THE TRANSMITTER ID IS OFFSET TO THE RANGE ABOVE, BASED ON WHICH BUTTON IS PRESSED.

BUTTON OFFSET TABLE

LEFT

RIGHT

TOP

BOTTOM LEFT OR RIGHT

0

16384 32768

49152

= S W I T C H O N

SET XMTR FACILITY CODE
SWITCHES TO MATCH THE FACILITY
CODE PRE-PROGRAMMED INTO
TRANSMITTER BLOCK

NOTE: THE FACTORY SETTINGS
OF FACILITY CODE "0" WILL
ALLOW VALIDATION OF ANY
TRANSMITTER FACILITY CODE

SW

T

0

SW

T

1

SW

T

2

SW

T

3

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

1 4

1 5

0

TRANSMITTER BLOCK
FACILITY CODE 0-15
(ASSIGNED WHEN
TRANSMITTER BLOCK IS
ORDERED FROM LINEAR)

= S W I T C H O F F

XMTR FACILITY
CODE SWITCHES

BOTH

FUNCTION

AS LEFT
BUTTON

LEFT

BUTTON

RIGHT

BUTTON

TOP

BUTTON

TOP

BUTTON

LEFT

BUTTON

RIGHT

BUTTON

BOTTOM-RIGHT

BUTTON

BOTTOM-LEFT

BUTTON

LEFT

BUTTON

LEFT

BUTTON

RIGHT

BUTTON

OPERATE

AS TOP

BUTTON

THE FACTORY SETTING ALLOWS ALL
TRANSMITTER BUTTONS TO OPERATE

SET XMTR BUTTON DISABLE SWITCH(ES) ON TO
PREVENT SELECTED TRANSMITTER BUTTONS
FROM OPERATING

SWITCH 4 - TOP
SWITCH 5 - BOTTOM RIGHT
SWITCH 6 - BOTTOM LEFT
SWITCH 7 - RIGHT OR TOP RIGHT
SWITCH 8 - LEFT OR TOP LEFT