Postscript – Lexmark C762 User Manual

Page 246

Advertising
background image

PostScript

4-69

MaxSourceList

integer

(Read-only) See Table C-4 on page C-9 for the default value
of your printer.

MaxUPathCache

integer

Maximum bytes occupied by the user path cache.

Legal value: Any non-negative integer.

PageCount

integer

(Read-only) Total number of pages that have been printed.

PanelCode

1

string

(Read-only) Version of the operator panel code.

PrinterCode

1

string

(Read-only) Firmware version of the printer controller card.

PrinterName

string

Initialized from the printer name stored in NVRAM (the default
name of the printer). If this parameter is set to a zero length
string, the

PrinterName

is set to the value of the product

string in

statusdict

.

Legal value: Any string of 32 or fewer non-null characters.

RamSize

integer

(Read-only) Total amount of memory (in bytes) installed in the
printer.

RealFormat

string

(Read-only) Preferred representation for real numbers in
binary encoded tokens.

Revision

integer

(Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.

SearchBuiltinFontsFirst

1

boolean

Controls the device search order the interpreter uses to
locate fonts.

SerialNumber

1

string

(Read-only) Serial number of your printer.

StartJobPassword

string

(Write-only) Controls the ability of the

startjob

operator to

alter initial Virtual Memory (VM).

Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.

StartupMode

integer

Controls the system start file (Sys/Start) during PostScript
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.

0

Disable use of Sys/Start file and Job/Start file.

1

Sys/Start file executes (if present on disk or flash).

10

Job/Start file executes before each user job.

11

Both files run (a combination of 1 and 10).

Legal Values: 0 <= x <= 255. Values other than the four listed
are equivalent to 0.

Note:

If both flash and disk have a Sys/Start file and Job/Start

file, the value of the SearchOrder for the two devices
determines which file is executed.

StaticRamSize

1

integer

(Read-only) Amount of static memory (in bytes) on the
controller board.

Table 4-10: PostScript Emulation System Parameters (Continued)

Key

Type

Definition

1

These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.

2

These parameters are available with the Adobe PostScript Language Supplement 3010.

3

These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 3010.