VALUE 10

TM

CONDENSING UNIT

Value 10 condensing units are designed for expansion

valve (TXV) and RFC systems. Refer to Lennox engi-

neering handbook for expansion valve kits which must

be ordered separately.

SHIPPING AND PACKING LIST

1-- Assembled 10ACB condensing unit
1-- 45- copper street elbow
1-- RFCIV refrigerant metering device (bullet)
1-- Coupling -- 5/16 x 3/8” (18, 24, 30)

Check unit for shipping damage. Consult last carrier

immediately if damage is found.

GENERAL INFORMATION

These instructions are intended as a general guide and

do not supersede national or local codes in any way.

Authorities having jurisdiction should be consulted be-

fore installation.

IMPORTANT

The Clean Air Act of 1990 bans the intentional

venting of refrigerant (CFC’s and HCFC’s) as of July

1, 1992. Approved methods of recovery, recycling

or reclaiming must be followed. Fines and/or in-

carceration may be levied for non--compliance.

INSTALLATION

INSTRUCTIONS

9DOXH

%

6HULHV

$&% &RQGHQVLQJ 8QLWV

&21'(16,1* 81,76

1--1/2 through 5 ton

503,800M

2/98

Supersedes 503,755M

TABLE OF CONTENTS

VALUE 10 CONDENSING UNIT

1

. . . . . . . . . . . . . . . . . . . . .

SHIPPING AND PACKING LIST

1

. . . . . . . . . . . . . . . . . . . . . .

GENERAL INFORMATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

10ACB UNIT DIMENSIONS

2

. . . . . . . . . . . . . . . . . . . . . . . . .

SETTING THE UNIT

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTRICAL

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PLUMBING

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REFRIGERANT METERING DEVICE

4

. . . . . . . . . . . . . . . . . .

MANIFOLD GAUGE SET

5

. . . . . . . . . . . . . . . . . . . . . . . . . . .

LIQUID & SUCTION LINE SERVICE VALVES

5

. . . . . . . . . .

LEAK TESTING

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EVACUATION

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START-UP

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CHARGING CONSIDERATIONS

8

. . . . . . . . . . . . . . . . . . . . .

CHARGING FOR RFC SYSTEMS

9

. . . . . . . . . . . . . . . . . . . .

CHARGING FOR TXV SYSTEMS

10

. . . . . . . . . . . . . . . . . . .

SYSTEM OPERATION

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10ACB CHECK POINTS

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WARNING

Product contains fiberglass wool.
Disturbing the insulation in this product during

installation, maintenance, or repair will expose

you to fiberglass wool. Breathing this may cause

lung cancer. (Fiberglass wool is known to the

State of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,

and eye irritation.
To reduce exposure to this substance or for further

information, consult material safety data sheets

available from address shown below, or contact

your supervisor.